APL5933A/B/C/D
Electrical Characteristics
Unless otherwise specified. These specifications apply over VCNTL=5V, vIN=1.8v, VOUT=1.2V, and TA= -40 ~ 85oC, unless otherwise
specified. Typical values are at TJ=25oC.
APL5933A/B/C/D
Symbol
Parameter
Test Conditions
Unit
Min.
Typ.
Max.
SUPPLY CURRENT
IVCNTL
ISD
VCNTL Supply Current
EN=VCNTL, IOUT=0A
-
-
1.0
20
1.5
30
mA
VCNTL Supply Current at
Shutdown
EN=GND or ENB=VCNTL
mA
VIN Supply Current at
Shutdown
VIN=5.5V, EN=GND or ENB=VCNTL
-
-
1
mA
POWER-ON-RESET (POR)
Rising VCNTL POR Threshold
2.5
-
2.7
0.4
0.9
0.5
2.9
-
V
V
V
V
VCNTL POR Hysteresis
Rising VIN POR Threshold
VIN POR Hysteresis
0.8
-
1.0
-
OUTPUT VOLTAGE
VREF
Reference Voltage
FB=VOUT
0.792
-1.5
0.8
-
0.808
+1.5
V
VCNTL =3.0~5.5V, IOUT= 0~3A,
TJ= -40~125 oC
Output Voltage Accuracy
%
Load Regulation
IOUT=0A ~3A
-
0.06
0.25
+0.15
-
%
%/V
W
Line Regulation
IOUT=10mA, VCNTL=3.0 ~ 5.5V
VCNTL=5V, VEN=0V or VENB=5V, VOUT<0.8V
VFB=0.8V
-0.15
-
-
80
-
VOUT Pull-Low Resistance
FB Input Current
-100
100
nA
DROPOUT VOLTAGES
TJ=25oC
VOUT=2.5V
-
-
-
-
-
-
0.24
0.29
0.39
0.26
0.35
0.25
0.34
TJ=-40~125oC
-
0.22
-
TJ=25oC
VCNTL=5.0V,
VDROP
VIN-to-VOUT Dropout Voltage
IOUT=3A
VOUT=1.8V
VOUT=1.2V
V
TJ=-40~125oC
TJ=25oC
0.21
-
TJ=-40~125oC
PROTECTIONS
TJ=25oC
3.6
3.2
-
4.0
-
4.6
ILIM
Current-Limit Level
A
TJ= -40 ~ 125oC
-
-
-
-
-
ISHORT
Short Current-Limit Level
VFB<0.2V
0.9
3.4
150
50
A
Short Current-Limit Blanking Time From beginning of soft-start
Thermal Shutdown Temperature TJ rising
Thermal Shutdown Hysteresis
1.5
-
ms
oC
oC
TSD
-
Copyright ã ANPEC Electronics Corp.
4
www.anpec.com.tw
Rev. A.5 - Aug., 2017