AMIS-30622
6. AC-Parameters
The AC parameters are given for Vbb and temperature in their operating ranges
Symbol
Pin(s)
Parameter
Power-up time
Test Conditions
Min
Typ
Max
10
Unit
ms
Power-up
Tpu
Internal oscillator
fosc
I2C Transceiver
Frequency of internal oscillator
SCL clock frequency
3.6
4.0
4.4
MHz
fSCL
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
0
0
100
360
kHz
kHz
µs
4.0
Hold time (repeated) START
condition. After this period, the first
clock pulse is generated.
tHD;STA
fSCL ≤ 360kHz
0.6
µs
4.7
1.3
4.0
0.6
4.7
0.6
250
100
µs
µs
µs
µs
µs
µs
ns
ns
ns
ns
ns
ns
µs
µs
µs
µs
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
fSCL ≤ 360kHz
fSCL ≤ 100kHz
fSCL ≤ 360kHz
LOW period of the SCK clock
tLOW
HIGH period of the SCK clock
tHIGH
Set-up time for a repeated START
condition
tSU;STA
tSU;DAT
SDA
SCK
Data set-up time
1000
300
300
300
Rise time of both SDA and SCK
signals (1)
tr
20+0.1Cb
Fall time of both SDA and SCK
signals (1)
tf
20+0.1Cb
4.0
tSU;STO
Set-up time for STOP condition
0.6
4.7
Bus free time between a STOP and
START condition
tBUF
tSP
1.3
Pulse width of spikes which must
be suppressed by the input filter
50
ns
Cb
Ci
Capacitive load for each bus line
Capacitance for each I/O pin
400
10
pF
pF
Switch input and hardwire address input
Tsw
SWI Scan pulse period (2)
HW
1024
1/16
µs
Tsw
Tsw_on
Motordriver
fpwm
Scan pulse duration
PWM frequency (2)
Turn-on transient time
Turn-off transient time
18
20
350
250
22
kHz
ns
ns
MOTxx
Tbrise
Between 10% and 90%
Tbfall
Charge pump
CPN
CPP
fCP
Notes
Charge pump frequency (2)
250
kHz
(1) Cb = total capacitance of one bus line in pF
(2) Derived from the internal oscillator