AMIS−30621
APPLICATIONS
The AMIS−30621 is ideally suited for small positioning
surveillance, satellite dish, renewable energy systems).
Suitable applications typically have multiple axes or require
mechatronic solutions with the driver chip mounted directly
on the motor.
applications. Target markets include: automotive (headlamp
alignment, HVAC, idle control, cruise control), industrial
equipment (lighting, fluid control, labeling, process control,
XYZ tables, robots...) and building automation (HVAC,
Table 1. ORDERING INFORMATION
†
Part No.
Peak Current
800 mA
UV*
High
High
Low
Low
Low
Low
Package
Shipping
AMIS30621C6213G
AMIS30621C6213RG
AMIS30621C6216G
AMIS30621C6216RG
AMIS30621C6217G**
AMIS30621C6217RG**
Tube / Tray
Tape & Reel
Tube / Tray
Tape & Reel
Tube / Tray
Tape & Reel
SOIC−20
(Pb−Free)
800 mA
800 mA
NQFP−32 (7 x 7 mm)
(Pb−Free)
800 mA
800 mA
SOIC−20
(Pb−Free)
800 mA
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specification Brochure, BRD8011/D.
*UV undervoltage lock out levels: see DC Parameters UV1 & UV2 (Stop Voltage thresholds).
** For prodcut versions AMIS30621C6217G and AMIS30621C6217RG the Ihold0 bit in OTP is programmed to ‘1’.
QUICK REFERENCE DATA
Table 2. ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Min
Max
Unit
V
V
, VHW2, VSWI
Supply voltage, Hardwired Address and SWI Pins
−0.3
+40
V
BB
(Note 1)
Bus input voltage
−40
−50
−55
−4
+40
+175
+160
+4
V
lin
J
T
Junction temperature range (Note 2)
Storage temperature
°C
°C
kV
T
st
V
esd
Human Body Model Electrostatic discharge voltage on LIN
pin (Note 3)
Human Body Model Electrostatic discharge voltage on other
pins (Note 3)
−2
+2
kV
V
CDM Electrostatic discharge voltage on other pins (Note 4)
−500
+500
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. For limited time: V < 0.5 s, SWI and HW2 pins < 1.0 s.
BB
2. The circuit functionality is not guaranteed.
3. Human Body Model according to MIL−STD−883 Method 3015.7, measured on SOIC devices, and according to AEC−Q100:
EIA−JESD22−A114−B (100 pF via 1.5 kW) measured on NQFP device.
4. CDM according to EOS_ESD−DS5.3−1993 (draft)−socketed mode, measured on SOIC devices, and according to AEC−Q100:
EIA−JESD22−A115−A measured on NQFP devices.
Table 3. OPERATING RANGES
Symbol
Parameter
Min
+6.5
−40
Max
+29
Unit
V
V
BB
Supply voltage
Operating temperature range (Note 5)
T
J
+165
°C
5. Note that the thermal warning and shutdown will get active at the level specified in the “DC Parameters”. No more than 100 cumulated hours
in life time above T .
tw
http://onsemi.com