GN (AGN)
3) High sensitivity single side stable type
Nominal operating
current
[10%] (at 20C 68F)
Nominal coil
voltage
Set voltage
(at 20C 68F)
Reset voltage
(at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. applied voltage
(at 20C 68F)
1.5V DC
3V DC
66.7mA
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
22.5
90
4.5V DC
6V DC
202.5
360
150%V of
nominal voltage
100mW
120mW
80%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
9V DC
810
12V DC
1,440
120%V of
nominal voltage
24V DC
5.0mA
4,800
*Pulse drive (JIS C 5442-1996)
2. Specifications
Characteristics
Item
Specifications
Arrangement
Initial contact resistance, max.
2 Form C
Contact
Max. 100 m (By voltage drop 6 V DC 1A)
Contact material
Stationary contact: AgPd+Au clad Movable contact: AgPd
1 A 30 V DC, 0.3 A 125 V AC (resistive load)
30 W (DC), 37.5 V A (AC) (resistive load)
110 V DC, 125 V AC
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Single side stable
1 A
Rating
10A 10 mV DC
140mW (1.5 to 12 V DC), 230mW (24 V DC)
Nominal operating
power
High sensitivity single side
stable type
100mW (1.5 to 12 V DC), 120mW (24 V DC)
1 coil latching
Min. 1,000M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Insulation resistance (Initial)
Between open contacts
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10160s) (FCC Part 68)
2,500 V (210s) (Telcordia)
Breakdown voltage
(Initial)
Between contact and coil
Between contact sets
Electrical
characteristics
Between open contacts
Between contacts and coil
Surge breakdown
voltage (Initial)
Max. 50C
Temperature rise (at 20C 68F)
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Operate time [Set time] (at 20C 68F)
Release time [Reset time] (at 20C 68F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Functional
Shock resistance
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 5 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Min. 5 107 (at 180 times/min.)
Min. 105 (1 A 30 V DC resistive), 105 (0.3 A 125 V AC resistive) (at 20 times/min.)
Expected life
Conditions
Ambient temperature:
(Single side stable, 1 coil latching type) –40C to +85C –40F to +185F
(High sensitivity single side stable type) –40C to +70C –40F to +158F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
20 times/min.
Unit weight
Notes:
Approx. 1 g .035 oz
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
1. Max. switching capacity
2. Life curve
3. Mechanical life
Tested sample: AGN2004H, 15 pcs.;
Operating speed: 180 times/min
.
100
4
DC resistive load
AC resistive load
3.5
Pick-up voltage
Max.
Min.
1.0
50
40
3
2.5
2
30
DC 30V resistive load
Drop-out voltage
20
Max.
Min.
1.5
1
0.3
AC 125V
resistive load
10
0
0.5
0
30
0.2
0.4
0.6
0.8
1.0
1.2
0
10
30
50
100
No. of operations, ×104
Contact voltage, V
Switching current, A
ds_61007_en_gn: 280114D
3