Absolute Maximum Ratings
Parameter
Symbol
Minimum
Typical
Maximum
Unit
Notes
Storage Temperature
(non-operating)
TS
-40
+85
°C
1, 2, 3
Ambient Operating Temperature
Relative Humidity
TA
-40
10
+85
°C
%
V
1, 2, 3
1
RH
90
Supply Voltage
VCC3
VIN
3.6
1, 2
1
Low Speed Input Voltage
-0.5
VCC+0.5
V
[4]
Recommended Operating Conditions
Parameter
Symbol
Minimum
-5
Typical
Maximum
+70
Unit
°C
Notes
Case Operating Temperature
Supply Voltage
TC
3
5
VCC3
3.135
9.95
3.465
11.3
V
Data Rate
Gb/s
Transceiver Electrical Characteristics
(T = -5 °C to +70 °C, V 3 = 3.3 V 5%)
C
CC
Parameter
Symbol
Minimum
Typical
Maximum
Unit
Notes
Power Supply Noise Rejection
(peak-peak) under 1MHz
PSNR
2% of VCC
mV
6
Power Supply Noise Rejection
(peak-peak) 1MHz to 10 MHz
PSNR
3% of VCC
mV
6
Module supply current
Power Dissipation
ICC
425
605 (EOL)
mA
PDISS
1410
2100 (EOL)
mW
Low Speed Outputs:
MOD_NR, RX_LOS, MOD_ABS,
INTERRUPT
VOH
VOL
Host_VCC-0.5
0.0
Host_VCC+0.3
0.4
V
V
7
8
Low Speed Inputs:
TX_DIS, MOD_DESEL, P_DOWN/RST VIH
VIL
2.0
-0.5
VCC3+0.3
0.8
V
V
10
9
Notes:
1. Absolute Maximum Ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short
period of time. See Reliability Data Sheet for specific reliability performance.
2. Between Absolute Maximum Ratings and the Recommended Operating Conditions functional performance is not intended, device reliability
is not implied, and damage to the device may occur over an extended period of time.
3. The Ambient Operating Temperature limitations are based on the Case Operating Temperature limitations and are subject to the host system
thermal design.
4. Recommended Operating Conditions are those values for which functional performance and device reliability is implied
5. Vcc condition applies to supply voltage at the XFP module
6. Power Supply filtering on host board required as per XFP MSA specification
7. 4.7 kΩ to 10 kΩ resistor pull-up to host_V , measured at the host side of connector. I (max) = - 2 mA.
CC
OH
8. 4.7 kΩ to 10 kΩ resistor pull-up to host_V , measured at the host side of connector. I (max) = 2 mA.
CC
OL
9. 4.7 kΩ to 10 kΩ resistor pull-up to host_V , measured at the host side of connector. I (max) = 10 µA.
CC
IL
10. 4.7 kΩ to 10 kΩ resistor pull-up to host_V , measured at the host side of connector. I (max) = - 10 µA.
CC
IH
5