VER : A_2
update : 2017.04.12
AC-DC ITE / Household Power Module
AFD25 SERIES
25 Watts
KEY FEATURES
Low Standby <0.1W
Switching Power Module for PCB Mountable
Fully Encapsulated Plastic Case
Universal Input Range 90-264VAC, 47-440 Hz
Regulated Output and Low Ripple and Low Noise
Isolation Class II
Small Size as AFCN 10Watt with 25Watt Higher Power
CE, CB and UL Approval
3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
AFD25-5.1S
20W
AFD25-12S
25W
AFD25-15S
25W
AFD25-24S
25W
Max Output Wattage (W)
Voltage
90-264 VAC or 120-370 VDC
47-440 Hz
Frequency (Hz)
Current (Full load)
490 mA max. (115 VAC) / 320 mA max. (230 VAC)
30 A max. (115 VAC) / 60 A max. (230 VAC)
0.25 mA max. (230 VAC)
3.15 A slow blow type
Inrush Current (<2ms,Cold Start)
Leakage Current
Input
External Fuse (mandatory)
External Varistor (recommended)
External Thermistor (recommended)
Voltage (V.DC.)
14S471K
10R / 10φ
5.1V
12V
15V
24V
Voltage Accuracy
±2%
Current (mA) max
3922
2083
1666
1042
Maximum Capacitive Load
Minimum Load
2000uF
680uF
220uF
220uF
0%
Output
Line Regulation (LL-HL) (typ.)
Load Regulation (5-100%) (typ.)
Ripple & Noise
±1%
±3%.
±1%.
120mV max (Vp-p)
82%
150mV max (Vp-p)
86%
160mV max (Vp-p)
85%
240mV max (Vp-p)
86%
Efficiency (at 230 VAC)
Hold-up Time(typ)
36 ms (at 230VAC)
Over Power Protection
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity
Hiccup technique, auto-recovery
Zener diode clamp
Protection
Isolation
Hiccup mode, indefinite (automatic recovery)
3000V
-40°C…+70°C (with derating)
-40°C…+85°C
Environment
±0.05%/°C
95% RH
MTBF
>400,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
Case Material
2.07 x 1.08 x 0.93 Inches ( 52.5 x 27.5 x 23.5 mm ) Tolerance 0.5 mm
Plastic resin (flammability to UL 94V-0)
62 g
Physical
Weight
Cooling Method
Free air convection
Safety
EMC
Agency Approvals
UL/cUL 60950-1&IEC/EN60950-1, TUV IEC/EN60335-1,CE
EMI
EN 55032 class B
EN 55024
(Conducted & Radiated Emission)
EMS (Noise Immunity)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-