ADuM1234
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 6.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Parameter
Rating
Storage Temperature (TST)
Ambient Operating Temperature (TA)
Input Supply Voltage (VDD1
Output Supply Voltage1 (VDDA, VDDB
Input Voltage1 (VIA, VIB)
Output Voltage1
−55°C to +150°C
−40°C to +105°C
−0.5 V to +7.0 V
−0.5 V to +27 V
−0.5 V to VDDI + 0.5 V
1
)
)
ESD CAUTION
VOA
VOB
−0.5 V to VDDA + 0.5 V
−0.5 V to VDDB + 0.5 V
−700 VPEAK to +700 VPEAK
700 VPEAK
−20 mA to +20 mA
−100 kV/μs to +100 kV/μs
Input-to-Output Voltage2
Output Differential Voltage3
Output DC Current (IOA, IOB)
Common-Mode Transients4
1 All voltages are relative to their respective ground.
2 Input-to-output voltage is defined as GNDA − GND1 or GNDB − GND1.
3 Output differential voltage is defined as GNDA − GNDB.
4 Refers to common-mode transients across any insulation barrier.
Common-mode transients exceeding the absolute maximum ratings
may cause latch-up or permanent damage.
Table 7. Maximum Continuous Working Voltage1
Parameter
Max
Unit
Constraint
AC Voltage, Bipolar Waveform
AC Voltage, Unipolar Waveform
Basic Insulation
565
V peak
V peak
V peak
50-year minimum lifetime
700
Analog Devices recommended maximum working voltage
DC Voltage
Basic Insulation
700
V peak
Analog Devices recommended maximum working voltage
1 Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Rev. 0 | Page 5 of 12