ADM8832
SPECIFICATIONS
VCC = 2.6 V to 3.6 V, TA = −40°C to +85°C, unless otherwise noted; C1, C5, C6, C7 = 2.2 µF, C2, C3, C4, C8, C9 = 1 µF, CLKIN = 1 kHz in
blanking mode.
Table 1.
Parameter
Min
Typ
Max
3.6
400
140
1
Unit
V
Test Conditions
INPUT VOLTAGE, VCC
SUPPLY CURRENT, ICC
2.6
150
70
µA
µA
µA
Unloaded, Scanning Period
Unloaded, Blanking Period
Shutdown Mode, TA = 25°C
+5.1 V OUTPUT
Output Voltage
Output Current
5.0
5.1
4
5
50
80
70
10
5
5.2
5
8
V
IL = 10 µA to 8 mA
Scanning Period
mA
mA
µA
%
%
mV p-p
µs
Scanning Period, VCC > 2.7 V
Blanking Period
VCC = 3 V, IL = 5 mA (Scanning)
VCC = 3 V, IL = 200 µA (Blanking)
8 mA Load
200
Power Efficiency
Output Ripple
Transient Response
+15.3 V OUTPUT
Output Voltage
Output Current
IL Stepped from 10 µA to 8 mA
14.4
15.3
50
1
15.6
100
10
V
µA
µA
mV p-p
IL = 1 µA to 100 µA
Scanning Period
Blanking Period
IL = 100 µA
Output Ripple
−10.2 V OUTPUT
Output Voltage
Output Current
50
−10.4
−100
−10
−10.2
−50
−1
−9.6
V
µA
µA
IL = –1 µA to −100 µA
Scanning Period
Blanking Period
Output Ripple
50
mV p-p
%
%
IL = –100 µA
POWER EFFICIENCY
(+15.3 V and −10.2 V Outputs)
CHARGE PUMP FREQUENCY
CONTROL PINS
90
80
Relative to 5.1 V Output, IL = 100 µA (Scanning)
Relative to 5.1 V Output, IL = 10 µA (Blanking)
Scanning Period
60
100
140
kHz
SHDN
Input Voltage, VSHDN
0.3 VCC
V
SHDN Low = Shutdown Mode
SHDN High = Normal Mode
0.7 VCC
V
Digital Input Current
Digital Input Capacitance1
SCAN/BLANK
1
10
µA
pF
Input Voltage
0.3 VCC
V
Low = BLANK Period
High = SCAN Period
0.7 VCC
V
Digital Input Current
Digital Input Capacitance1
LDO_ON/OFF
1
10
µA
pF
Input Voltage
0.3 VCC
V
V
Low = External LDO
High = Internal LDO
0.7 VCC
Digital Input Current
Digital Input Capacitance1
Footnotes after table.
1
10
µA
pF
Rev. A | Page 3 of 12