ADM1034  
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
DRIVE1  
TACH1  
DRIVE2  
TACH2  
GND  
SCL  
SDA  
ADM1034  
TOP VIEW  
(Not to Scale)  
ALERT  
LOCATION  
D2+  
V
D2–  
CC  
THERM  
D1+  
FAN_FAULT/REF  
D1–  
Figure 3. Pin Configuration  
Table 3. Pin Function Descriptions  
Pin No.  
Mnemonic  
DRIVE1  
TACH1  
DRIVE2  
TACH2  
GND  
Description  
1
2
3
4
5
6
7
DRIVE1 Pin Drives Fan 1. Open-drain output. Requires a pull-up resistor.  
Fan 1 Fan Speed Measurement Input. Connects to the fan’s TACH output to measure the fan speed.  
DRIVE2 Pin Drives Fan 2. Open-drain output. Requires a pull-up resistor.  
Fan 2 Fan Speed Measurement Input. Connects to the fan’s TACH output to measure the fan speed.  
Ground for Analog and Digital Circuitry.  
Power. Can be powered by 3.3 V standby power if monitoring in low power states is required.  
Can be configured as an overtemperature interrupt output, or as an input (to monitor PROCHOT output of  
an INTEL CPU). A timer measures assertion times on the THERM pin (either input or output).  
VCC  
THERM  
8
FAN_FAULT/REF  
FAN_FAULT: Open-Drain Output. Asserted low when one or both fans stall. Requires a pull-up resistor to VCC.  
REF: Analog Input Reference for the THERM Input.  
9
D1−  
D1+  
D2−  
D2+  
Cathode Connection for the First Thermal Diode or Diode-Connected Transistor.  
Anode Connection for the First Thermal Diode or Diode-Connected Transistor.  
Cathode Connection for the Second Thermal Diode or Diode-Connected Transistor.  
Anode Connection for the Second Thermal Diode or Diode-Connected Transistor.  
8-Level Analog Input. Used to determine the correct SMBus version and the SMBus address (in  
fixed-and-discoverable mode) and to set the LLL bits in the UDID (in ARP-capable mode).  
Open-Drain Output. SMBusALERT pin. Alerts the system in the case of out-of-limit events, such as over  
temperature. Can be configured as sticky SMBus mode or comparator mode.  
Serial Bus Bidirectional Data. Connects to the SMBus master’s data line. Requires pull-up resistor if not  
provided elsewhere in the system.  
Serial SMBus Clock Input. Connects to the SMBus master’s clock line. Requires pull-up resistor if not already  
provided in the system.  
10  
11  
12  
13  
LOCATION  
14  
15  
16  
ALERT  
SDA  
SCL  
Rev. 0 | Page 7 of 40  
 

与ADM1034相关器件

型号 品牌 描述 获取价格 数据表
ADM1034ARQ ONSEMI SPECIALTY ANALOG CIRCUIT, PDSO16, MO-137AB, QSOP-16

获取价格

ADM1034ARQ-REEL ADI IC SPECIALTY ANALOG CIRCUIT, PDSO16, MO-137AB, QSOP-16, Analog IC:Other

获取价格

ADM1034ARQ-REEL ONSEMI 暂无描述

获取价格

ADM1034ARQ-REEL7 ONSEMI 暂无描述

获取价格

ADM1034ARQZ ONSEMI Thermal Monitor and Fan Speed (RPM) Controller

获取价格

ADM1034ARQZ-R7 ONSEMI SPECIALTY ANALOG CIRCUIT, PDSO16, LEAD FREE, MO-137AB, QSOP-16

获取价格