ADM1034
SPECIFICATIONS
TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted.1
Table 1.
Parameter
Min
Typ
Max
Unit
Test °onditions/°omments
POWER SUPPLY
Supply Voltage, VCC
Supply Current, ICC
2
3.0
3.30
3.6
3
900
V
mA
µA
V
Interface inactive, ADC active
Standby mode
Undervoltage Lockout Threshold
Power-On Reset Threshold
2.5
1
1
2.4
V
TEMPERATURE-TO-DIGITAL CONVERTER
Internal Sensor Accuracy
2
°C
20°C ≤ TA ≤ 60°C
+2
°C
−4
−40°C ≤ TA ≤ +100°C
Resolution
0.03125
°C
External Diode Sensor Accuracy
0.5
1
1
°C
−40°C ≤ TD ≤ +100°C; TA = +40°C
−40°C ≤ TD ≤ +100°C; +20°C ≤ TA ≤ +60°C
−40°C ≤ TD ≤ +100°C; −40°C ≤ TA ≤ +100°C
°C
+2
°C
−3
Resolution
0.03125
°C
Remote Sensor Source Current
85
34
5
µA
µΑ
µΑ
Ω
%/V
ms
ms
ms
High level
Mid level
Low level
Series Resistance Cancellation
Power Supply Sensitivity
Conversion Time (Local Temperature)
Conversion Time (Remote Temperature)
Total Conversion Time
1000
1
11
32
75
Averaging enabled
Averaging enabled
Averaging enabled
OPEN-DRAIN DIGITAL OUTPUTS
(ALERT, THERM, FAN_FAULT, DRIVE1, DRIVE2)3
Output Low Voltage, VOL
0.4
1
V
I
OUT = −6.0 mA; VCC = +3 V
High Level Output Leakage Current, IOH
DIGITAL INPUT LEAKAGE CURRENT
(TACH1, TACH2)
0.1
µA
VOUT = VCC; VCC = 3 V
Input High Current, IIH
µA
µA
pF
−1
−VIN = VCC
VIN = 0
Input Low Current, IIL
Input Capacitance, CIN
1
7
DIGITAL INPUT LOGIC LEVELS
(TACH1, TACH2)
Input High Voltage, VIH
Input Low Voltage, VIL
2.0
5.5
+0.8
V
V
−0.3
Hysteresis
500
0.1
mV p−p
OPEN-DRAIN SERIAL DATA
BUS OUTPUT (SDA)
Output Low Voltage, VOL
High Level Output Leakage Current, IOH
SERIAL BUS DIGITAL INPUTS
(SCL, SDA)
0.4
1
V
I
OUT = −6.0 mA; VCC
µA
VOUT = VCC
Input High Voltage, VIH
Input Low Voltage, VIL
Hysteresis
2.1
V
V
mV
0.8
500
Rev. 0 | Page 4 of 40