ADL5601
Data Sheet
Parameter
Test Conditions/Comments
Min
Typ
Max
Unit
FREQUENCY = 900 MHz
Gain
14.3
15.3
16.5
dB
vs. Frequency
50 MHz
0.01
dB
vs. Temperature
−40°C ≤ TA ≤ +85°C
4.75 V to 5.25 V
0.22
0.02
19.0
43.0
−57.6
−78.7
3.7
dB
dB
vs. Supply Voltage
Output 1 dB Compression Point (P1dB)
Output Third-Order Intercept (OIP3)
Second Harmonic
Third Harmonic
18.0
dBm
dBm
dBc
dBc
dB
Δf = 1 MHz, output power (POUT) = 0 dBm per tone
POUT = 0 dBm
POUT = 0 dBm
Noise Figure
FREQUENCY = 2000 MHz
Gain
14.2
0.08
0.27
0.03
17.5
34.2
−41.9
−67.3
4.5
dB
dB
dB
dB
dBm
dBm
dBc
dBc
dB
vs. Frequency
vs. Temperature
50 MHz
−40°C ≤ TA ≤ +85°C
4.75 V to 5.25 V
vs. Supply Voltage
Output 1 dB Compression Point (P1dB)
Output Third-Order Intercept (OIP3)
Second Harmonic
Third Harmonic
Δf = 1 MHz, output power (POUT) = 0 dBm per tone
POUT = 0 dBm
POUT = 0 dBm
Noise Figure
FREQUENCY = 2600 MHz
Gain
13.4
0.04
0.20
0.04
16.0
30.7
−46.4
−65.4
4.7
dB
dB
dB
dB
dBm
dBm
dBc
dBc
dB
vs. Frequency
vs. Temperature
50 MHz
−40°C ≤ TA ≤ +85°C
4.75 V to 5.25 V
vs. Supply Voltage
Output 1 dB Compression Point (P1dB)
Output Third-Order Intercept (OIP3)
Second Harmonic
Third Harmonic
Δf = 1 MHz, output power (POUT) = 0 dBm per tone
POUT = 0 dBm
POUT = 0 dBm
Noise Figure
FREQUENCY = 3500 MHz
Gain
12.9
0.06
0.32
0.05
14.2
26.7
−41.0
−62.4
5.5
dB
dB
dB
dB
dBm
dBm
dBc
dBc
dB
vs. Frequency
vs. Temperature
50 MHz
−40°C ≤ TA ≤ +85°C
4.75 V to 5.25 V
vs. Supply Voltage
Output 1 dB Compression Point (P1dB)
Output Third-Order Intercept (OIP3)
Second Harmonic
Third Harmonic
Δf = 1 MHz, output power (POUT) = 0 dBm per tone
POUT = 0 dBm
POUT = 0 dBm
Noise Figure
FREQUENCY = 4000 MHz
Gain
12.1
0.11
0.50
0.05
12.7
24.7
−41.0
−59.7
6.1
dB
dB
dB
dB
dBm
dBm
dBc
dBc
dB
vs. Frequency
vs. Temperature
50 MHz
−40°C ≤ TA ≤ +85°C
4.75 V to 5.25 V
vs. Supply Voltage
Output 1 dB Compression Point (P1dB)
Output Third-Order Intercept (OIP3)
Second Harmonic
Third Harmonic
Δf = 1 MHz, output power (POUT) = 0 dBm per tone
POUT = 0 dBm
POUT = 0 dBm
Noise Figure
Rev. A | Page 4 of 16