DE (ADE)
RATING
1. Coil data
1) Single side stable type
Nominal operating
current
[ 10%] (at 20°C 68°F)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
5V DC
12V DC
24V DC
40 mA
16.6mA
8.3mA
125Ω
720Ω
2,880Ω
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
130%V of
nominal voltage
200mW
2) 2 coil latching type
Nominal operating
current
[ 10%] (at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
Set coil
40 mA
16.6mA
8.3mA
Reset coil
40 mA
16.6mA
8.3mA
Set coil
125Ω
720Ω
Reset coil
125Ω
720Ω
Set coil
200mW
Reset coil
200mW
5V DC
12V DC
24V DC
70%V or less of
nominal voltage
(Initial)
70%V or less of
nominal voltage
(Initial)
130%V of
nominal voltage
2,880Ω
2,880Ω
2. Specifications
Characteristics
Item
Specifications
1 Form A 1 Form B
Arrangement
1 Form A
2 Form A
Contact
Contact resistance (Initial)
Contact material
Max. 30 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
10A 250V AC, 10A 30V DC
2,500VA, 300W
250V AC, 30V DC
10A
8A 250V AC, 8A 30V DC
2,000VA, 240W
250V AC, 30V DC
8A
Rating
Max. switching current
Nominal operating power
200mW
Min. switching capacity*1
100mA 5V DC
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts
1,000 Vrms for 1 min. (Detection current: 10 mA)
Breakdown voltage
Between contact sets
(Initial)
—
4,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Electrical
characteristics
12,000 V
Temperature rise (coil) (at 70°C 158°F)
Max. 50°C 122°F (By resistive method)
Max. 10 ms [Max. 10 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Operate time [Set time] (at 20°C 68°F)
Max. 5 ms [Max. 10 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Release time [Reset time] (at 20°C 68°F)
Functional
Shock resistance
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 3 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
Min. 107 (at 300 times/min.)
Min. 105 (resistive load,
at 20 times/min., at AC nominal
Min. 105
switching capacity)
Min. 5×104 (resistive load,
at 20 times/min., at DC nominal
switching capacity)
Expected life
Electrical
(resistive load, at 20 times/min., at nominal switching capacity)
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Conditions for operation, transport and storage*3
Max. operating speed
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
20 times/min. (at nominal switching capacity)
Approx. 7 g .25 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB175E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/