ADDC02803SC/ADDC02805SA
PIN DESCRIPTIONS
ABSOLUTE MAXIMUM RATINGS*
INHIBIT . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V dc, –0.5 V dc
SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.0 V dc, –0.5 V dc
ISHARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V dc, –0.5 V dc
TEMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V dc, –0.3 V dc
Common-Mode Voltage, Input to Output . . . . . . . . . 500 V dc
Lead Soldering Temp (10 sec) . . . . . . . . . . . . . . . . . . . +300°C
Storage Temperature . . . . . . . . . . . . . . . . . . –65°C to +150°C
Maximum Junction Temperature . . . . . . . . . . . . . . . . +150°C
Maximum Case Operating Temperature . . . . . . . . . . . +125°C
Pin
No. Name
Function
1
–SENSE Feedback loop connection for remote sensing
output voltage. Must always be connected to
output return for proper operation.
+SENSE Feedback loop connection for remote sensing
output voltage. Must always be connected to
+VOUT for proper operation.
2
*Absolute maximum ratings are limiting values, to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability under any of these conditions is not necessarily implied. Exposure of
absolute maximum rating conditions for extended periods of time may affect
device reliability.
3
4
ADJUST Adjusts output voltage setpoint.
STATUS Indicates output voltage is within ±5% of
nominal. Active high referenced to –SENSE
(Pin 1).
5
6
7
8
VAUX
Low level dc auxiliary voltage supply refer-
enced to input return (Pin 10).
ORDERING INFORMATION
INHIBIT Power Supply Inhibit. Active low and refer-
Operating
Temperature
Range (Case) Description
enced to input return (Pin 10).
Clock synchronization input for multiple
units; referenced to input return (Pin 10).
Current share pin which allows paralleled
units to share current typically within ±5% at
full load; referenced to input return (Pin 10).
Device
SYNC
ISHARE
ADDC02803SCKV
ADDC02803SCTV
5962-9760101HXC
–40°C to +85°C Hermetic Package
–55°C to +90°C Hermetic Package
(ADDC2803SCTV/QMLH) –55°C to +125°C Hermetic Package
9
TEMP
Case temperature indicator and temperature
shutdown override; referenced to input return
(Pin 10).
Input Return.
+28 V Nominal Input Bus.
+5 V dc Output (ADDC02805SA).
+3.3 V dc Output (ADDC02803SC).
+5 V dc Output (ADDC02805SA).
+3.3 V dc Output (ADDC02803SC).
+5 V dc Output (ADDC02805SA).
+3.3 V dc Output (ADDC02803SC).
ADDC02805SAKV
ADDC02805SATV
5962-9570701HXC
–40°C to +85°C Hermetic Package
–55°C to +90°C Hermetic Package
10
11
12
–VIN
+VIN
+VOUT
(ADDC2805SATV/QMLH) –55°C to +125°C Hermetic Package
EXPLANATION OF TEST LEVELS
Test Level
13
14
+VOUT
+VOUT
I
–
–
100% production tested.
II
100% production tested at +25°C, and sample tested at
specified temperatures.
15
16
17
RETURN Output Return.
RETURN Output Return.
RETURN Output Return.
III – Sample tested only.
IV – Parameter is guaranteed by design and characterization
testing.
V
–
Parameter is a typical value only.
PIN CONFIGURATION
VI – All devices are 100% production tested at +25°C. 100%
production tested at temperature extremes for military
temperature devices; guaranteed by design and charac-
terization testing for industrial devices.
1
17
12
TOP
VIEW
11
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss
of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. A