8页 205K
描述
Thermocouple Conditioner and Setpoint Controller

AD597* 技术参数

是否无铅: 含铅是否Rohs认证: 符合
生命周期:Active零件包装代码:SOIC
包装说明:SOP,针数:8
Reach Compliance Code:compliantECCN代码:EAR99
HTS代码:8542.39.00.01风险等级:6.99
模拟集成电路 - 其他类型:ANALOG CIRCUITJESD-30 代码:R-PDSO-G8
JESD-609代码:e3长度:4.9 mm
湿度敏感等级:1负电源电压最大值(Vsup):-15 V
负电源电压最小值(Vsup):-2.5 V标称负供电电压 (Vsup):-5 V
功能数量:1端子数量:8
最高工作温度:125 °C最低工作温度:-40 °C
封装主体材料:PLASTIC/EPOXY封装代码:SOP
封装形状:RECTANGULAR封装形式:SMALL OUTLINE
峰值回流温度(摄氏度):260认证状态:Not Qualified
座面最大高度:1.75 mm最大供电电压 (Vsup):15 V
最小供电电压 (Vsup):2.5 V标称供电电压 (Vsup):5 V
表面贴装:YES温度等级:AUTOMOTIVE
端子面层:Matte Tin (Sn)端子形式:GULL WING
端子节距:1.27 mm端子位置:DUAL
处于峰值回流温度下的最长时间:30宽度:3.9 mm
Base Number Matches:1

AD597* 数据手册

 浏览型号AD597*的Datasheet PDF文件第2页浏览型号AD597*的Datasheet PDF文件第3页浏览型号AD597*的Datasheet PDF文件第4页浏览型号AD597*的Datasheet PDF文件第5页浏览型号AD597*的Datasheet PDF文件第7页浏览型号AD597*的Datasheet PDF文件第8页 
AD596/AD597  
temperature differences will result in a direct error at the out-  
put. In the temperature proportional mode, the alarm feature  
will only activate in the event of an open thermocouple or sys-  
tem transient which causes the device output to saturate.  
Self-Heating errors will not effect the operation of the alarm but  
two cases do need to be considered. First, after a fault is cor-  
rected and the alarm is reset, the AD596/AD597 must be al-  
lowed to cool before readings can again be accurate. T his can  
take 5 minutes or more depending upon the thermal environ-  
ment seen by the device. Second, the junction temperature of  
the part should not be allowed to exceed 150°C. If the alarm  
circuit of the AD596/AD597 is made to source or sink 20 mA  
with 30 V across it, the junction temperature will be 90°C above  
ambient causing the die temperature to exceed 150°C when  
ambient is above 60°C. In this case, either the load must be  
reduced, or a heat sink used to lower the thermal resistance.  
SINGLE AND D UAL SUP P LY CO NNECTIO NS  
In the single supply configuration as used in the setpoint con-  
troller of Figure 2, any convenient voltage from +5 V to +36 V  
may be used, with self-heating errors being minimized at lower  
supply levels. In this configuration, the –VS connection at Pin 5  
is tied to ground. T emperatures below zero can be accommo-  
dated in the single supply setpoint mode, but not in the single  
supply temperature measuring mode (Figure 1 reconnected for  
single supply). T emperatures below zero can only be indicated  
by a negative output voltage, which is impossible in the single  
supply mode.  
Common-mode voltages on the thermocouple inputs must  
remain below the positive supply, and not more than 0.15 V  
more negative than the minus supply. In addition, a return path  
for the input bias currents must be provided. If the thermo-  
couple is not remotely grounded, then the dotted line connec-  
tions in Figures 1 and 2 are mandatory.  
TEMP ERATURE READ O UT AND CO NTRO L  
Figure 6 shows a complete temperature indication and control  
system based on the AD596/AD597. Here the AD596/AD597 is  
being used as a closed-loop thermocouple signal conditioner  
and an external op amp is used to implement setpoint. T his has  
two important advantages. It provides a high level (10 mV/°C)  
output for the A/D panel meter and also preserves the alarm  
function for open thermocouples.  
STABILITY O VER TEMP ERATURE  
T he AD596/AD597 is specified for a maximum error of ±4°C at  
an ambient temperature of 60°C and a measuring junction  
temperature at 175°C. T he ambient temperature stability is  
specified to be a maximum of 0.05°C/°C. In other words, for  
every degree change in the ambient temperature, the output will  
change no more than 0.05 degrees. So, at 25°C the maximum  
deviation from the temperature-voltage characteristic of T able I  
is ±5.75°C, and at 100°C it is ±6°C maximum (see Figure 5). If  
the offset error of ±4°C is removed with a single offset adjust-  
ment, these errors will be reduced to ±1.75°C and ±2°C max.  
T he optional trim circuit shown in Figure 1 demonstrates how  
the ambient offset error can be adjusted to zero.  
T he A/D panel meter can easily be offset and scaled as shown to  
read directly in degrees Fahrenheit. If a two temperature cali-  
bration scheme is used, the dominant residual errors will arise  
from two sources; the ambient temperature rejection (typically  
±2°C over a 25°C to 100°C range) and thermocouple nonlin-  
earity typical +1°C from 80°C to 550°C for type J and +1°C  
from –20°C to 350°C for type K.  
+2.0؇C  
+1.75؇C  
An external voltage reference is used both to increase the stabil-  
ity of the A/D converter and supply a stable reference for the  
setpoint voltage.  
MAXIMUM  
A traditional requirement for the design of setpoint control  
thermocouple systems has been to configure the system such  
that the appropriate action is taken in the event of an open  
thermocouple. T he open thermocouple alarm pin with its flex-  
ible current-limited output format supports this function when  
the part operates in the temperature proportional mode. In  
addition, if the thermocouple is not remotely grounded, it is  
possible to program the device for either a positive or negative  
full-scale output in the event of an open thermocouple. T his is  
done by connecting the bias return resistor directly to Pin 1 if a  
high output voltage is desired to indicate a fault condition. Al-  
ternately, if the bias return is provided on the thermocouple lead  
connected to Pin 2, an open circuit will result in an output low  
reading. Figure 6 shows the ground return connected to Pin 1  
so that if the thermocouple fails, the heater will remain off. At  
the same time, the alarm circuit lights the LED signalling the  
need to service the thermocouple. Grounding Pin 2 would lead  
to low output voltage saturation, and in this circuit would result  
in a potentially dangerous thermal runaway under fault conditions.  
+0.8؇C  
0
TYPICAL  
–0.8؇C  
MAXIMUM  
–1.75؇C  
–2.0؇C  
25؇C  
60؇C  
100؇C  
Figure 5. Drift Error vs. Tem perature  
TH ERMAL ENVIRO NMENTAL EFFECTS  
T he inherent low power dissipation of the AD596/AD597 keeps  
self-heating errors to a minimum. However, device output is  
capable of delivering ±5 mA to an external load and the alarm  
circuitry can supply up to 20 mA. Since the typical junction to  
ambient thermal resistance in free air is 150°C/W, significant  
temperature difference between the package pins (where the  
reference junction is located) and the chip (where the cold junc-  
tion temperature is measured and then compensated) can exist  
when the device is operated in a high dissipation mode. T hese  
–6–  
REV. B  

与AD597*相关器件

型号 品牌 描述 获取价格 数据表
AD-5970S BOTHHAND ADSL LINE TRANSFORMER

获取价格

AD597AH ADI Thermocouple Conditioner and Setpoint Controller

获取价格

AD597AHZ ADI Thermocouple Conditioner and Setpoint Controller

获取价格

AD597AHZ ROCHESTER SPECIALTY ANALOG CIRCUIT, MBCY10, METAL CAN, TO-100, 10 PIN

获取价格

AD597AR ADI Thermocouple Conditioner and Setpoint Controller

获取价格

AD597AR ROCHESTER SPECIALTY ANALOG CIRCUIT, PDSO8, PLASTIC, SOIC-8

获取价格