AD5040/AD5060
ABSOLUTE MAXIMUM RATINGS
Table 4.
Parameter
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Rating
VDD to GND
Digital Input Voltage to GND
VOUT to GND
VREF to GND
Operating Temperature Range
Industrial (A, B Grade)
Extended Automotive Temperature
Range (Y Grade)
Storage Temperature Range
Maximum Junction Temperature
SOT-23 Package
−0.3 V to +7.0 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−40°C to +85°C
−40°C to +125°C
This device is a high performance integrated circuit with an
ESD rating of <2 kV. It is ESD sensitive. Proper precautions
should be taken for handling and assembly.
−65°C to +150°C
150°C
Power Dissipation
(TJ max − TA)/θJA
206°C/W
91°C/W
θJA Thermal Impedance
θJc Thermal Impedance
Reflow Soldering (Pb-free)
Peak Temperature
260°C
Time-at-Peak Temperature
ESD (AD5040/AD5060)
10 sec to 40 sec
1. 5 kV
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. A | Page 6 of 24