AAT2807A
Dual High Efficiency Charge Pump
for White LED and Flash Applications
Electrical Characteristics1
VIN = 3.5V; CIN = COUT = C1 = C2 = C3 = 1.0µF; TA = -40°C to 85°C, unless otherwise noted.
Typical values are at TA = 25°C.
Symbol Description
Input Power Supply
Conditions
Min Typ Max Units
VIN
Operation Range
2.7
5.5
1
V
1X Mode, 3.0 ≤ VIN ≤ 5.5, Active, No Load
Current; EN_FLSH = GND, EN/SET = VIN
1.5X Mode, 3.0 ≤ VIN ≤ 5.5, Active, No Load
Current; EN_FLSH = GND, EN/SET = VIN
2X Mode, 3.0 ≤ VIN ≤ 5.5, Active, No Load
Current; EN_FLSH = GND, EN/SET = VIN
3.0 ≤ VIN ≤ 5.5, No Load Current;
EN_FLSH = VIN, EN/SET= GND
0.3
1.0
1.0
2.0
3.0
3.0
4.5
ICC
Operating Current
mA
ISHDN
IDX
Shutdown Current
EN_FLSH = EN/SET=0
1.0
12
µA
%
2, 4
Input Current Accuracy
ISET = 20mA; TA = 25°C
-12
I(D-Match)
Current Matching Between Any
Two Current Sink Inputs
VD1:D3 = 3.6, VIN = 3.5V
0.5
7
%
2,5
2
RSINK
Sink Switch Impedance (each)
Flash Charge Pump Output
Voltage
Ω
V
VOUT_FL
3.0V < VIN < 5V, IOUT = 100mA;
EN_FLSH = VIN
4.3 4.5
4.8
Continuous Maximum Output
Current Flash Charge Pump
EN_FLSH = VIN
150
3
IDX_FLSH
mA
%
Pulsed Maximum Output Current TPULSE = 250ms; VIN = 3.6V;
300
3
Flash Charge Pump
EN_FLSH = VIN
ηCP
Charge Pump Section Efficiency VIN = 3.5V, IOUT(TOTAL) = 120mA,
Measured from IN to CP
93
TSS
Soft-Start Time
100
1.0
µs
MHz
V
FCLK
Clock Frequency
VEN(L)
VEN(H)
Enable Threshold Low
0.4
75
Enable Threshold High
1.4
0.3
50
V
TEN/SET LO EN/SET Low Time
VEN/SET < 0.6V
VEN/SET> 1.4V
µs
ns
TEN/SET HI Minimum EN/SET High Time
TOFF
TLAT
II
EN/SET Off Timeout
EN/SET Latch Timeout
Enable and EN/SET Input
Leakage
VEN/SET< 0.6V
500
500
1.0
µs
µs
µA
VEN/SET> 1.4V
VEN/SET= VEN_FLSH = VIN
-1.0
Notes:
1. The AAT2807A is guaranteed to meet performance specifications over the -40°C to 85°C operating temperature range and is assured
by design, characterization, and correlation with statistical process controls.
2. Specification applies only to the tri-mode charge pump.
3. Specification applies only to the charge pump doubler.
4. Determined by the sum of all active channels.
5. Current matching is defined as the deviation of any sink current from the average of all active channels.
4
2807A.2004.12.1.0