DATA SHEET
AAT1162
12V, 1.5A Step-Down DC/DC Converter
Electrical Characteristics1
4.0V < VIN < 13.2V. CIN = COUT = 22μF; L = 2.2 or 3.8μH, TA = -40°C to +85°C, unless otherwise noted. Typical values
are at TA = 25°C.
Symbol Description
Conditions
Min Typ Max Units
VIN
Input Voltage Range
4.0
13.2
4.0
V
Rising
VUVLO
Input Under-Voltage Lockout
V
Hysteresis
No Load
VEN = GND
0.3
150
IQ
ISHDN
Supply Current
Shutdown Current
300
1
μA
μA
0.94
VIN
2.5
VOUT
Output Voltage Range
Output Voltage Accuracy
Line Regulation
0.6
V
%
VOUT
VOUT
VOUT/VIN
VOUT
IOUT = 0A to 1.5A
-2.5
/
VIN = 4.5V to 13.2V
0.023 0.100
0.4
%/V
/
Load Regulation
VIN = 12V, VOUT = 5V, IOUT = 0A to 1.5A
%
V
IOUT
VFB
Feedback Reference Voltage (adjustable version) No Load, TA = 25°C
0.59 0.60
0.61
0.2
Adjustable Version
Fixed Version
IFBLEAK
FOSC
FB Leakage Current
VOUT = 1.2V
μA
2
0.8
200
PWM Oscillator Frequency
Foldback Frequency
Maximum Duty Cycle
Minimum Turn-On Time
Soft-Start Time
0.6
1
MHz
kHz
%
ns
ms
DC
TON
TS
94
100
2
VIN = 12V
VIN = 6V
VIN = 12V
VIN = 6V
0.12
0.15
0.06
0.08
90
RDS(ON)H
RDS(ON)L
P-Channel On Resistance
N-Channel On Resistance
ILIM
ILXLEAK
TSD
THYS
VIL
Efficiency
PMOS Current Limit
LX Leakage Current
Over-Temperature Shutdown Threshold
Over-Temperature Shutdown Hysteresis
EN Logic Low Input Threshold
EN Logic High Input Threshold
EN Input Current
VIN = 12V, VOUT = 5V, IOUT = 1.5A
%
A
μA
°C
°C
V
4.0
6.0
VIN = 13.2V, VLX = 0 to VIN
1
140
25
0.4
1.0
VIH
IEN
1.4
-1.0
V
μA
VEN = 0V, VEN = 13.2V
1. The AAT1162 is guaranteed to meet performance specifications over the -40°C to +85°C operating temperature range and is assured by design, characterization, and correla-
tion with statistical process controls.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
4
201998B
• Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 20, 2013