A43L8316
DC Electrical Characteristics
(Recommended operating condition unless otherwise noted, TA = 0 to 70°C)
Speed
-8
CAS
Symbol
Parameter
Test Conditions
Burst Length = 1
Unit Notes
Latency
-7
-10
90
Operating Current
(One Bank Active)
3
2
110
120
100
100
Icc1
mA
mA
1
tRC ³ tRC(min), tCC ³ tCC(min), IOL =
0mA
90
Icc2 P
Precharge Standby
Current in power-
down mode
CKE £ VIL(max), tCC = 15ns
CKL £ VIL(max), tCC = ¥
3
2
3
2
3
2
Icc2 PS
CKE ³ VIH(min), CS ³ VIH(min), tCC = 15ns
ICC2N
25
6
25
6
25
6
Precharge Standby
Current in non
power-down mode
Input signals are changed one time during 30ns
mA
CKE ³ VIH(min), CLK £ VIL(max), tCC = ¥
ICC2NS
Input signals are stable.
ICC3 P
Active Standby
Current in power-
down mode
CKE £ VIL(max), tCC = 15ns
3
2
3
2
3
2
mA
mA
ICC3 PS
CKE £ VIL(max), CKE £ VIL(max) tCC = ¥
CKE ³ VIH(min), CS ³ VIH(min), tCC = 15ns
ICC3N
Active Standby
current in non
power-down mode
(One Bank Active)
30
30
30
Input signals are changed one time during 30ns
CKE ³ VIH(min), CLK £ VIL(max), tCC = ¥
ICC3NS
10
10
10
Input signals are stable.
3
160
150
140
Operating Current
(Burst Mode)
IOL = 0mA, Page Burst
ICC4
mA
mA
1
2
2
All bank Activated, tCCD = tCCD (min)
120
90
110
90
100
85
3
2
ICC5
ICC6
Refresh Current
tRC ³ tRC (min)
CKE £ 0.2V
100
90
85
Self Refresh
Current
2
2
2
mA
Note: 1. Measured with outputs open. Addresses are changed only one time during tCC(min).
2. Refresh period is 64ms. Addresses are changed only one time during tCC(min).
Preliminary (April, 2000, Version 1.0)
5
AMIC Technology, Inc.