APPLICABLE STANDARD
Operating
Storage
Temperature Range
-10 C to +60 C(2)
-55 C to +85 C(1)
Temperature Range
Operating
Humidity Range
Storage
Humidity Range
Relative humidity 85 % max (Not dewed)
Relative humidity 85 % max (Not dewed)
Rating
Voltage
Current
Applicable Cable
Insulation
200 V AC
1 A
-
-
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
×
×
×
×
Marking
ELECTRIC CHARACTERISTICS
Contact Resistance
Insulation Resistance
Voltage Proof
100 mA (DC or 1000 Hz).
15 mΩ MAX .
×
×
×
-
-
-
500 V DC.
1000 MΩ MIN.
650 V AC for 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Mechanical Operation
100 times insertions and extractions.
1) Contact Resistance: 20 m MAX.
×
×
×
-
-
-
2) No damage, crack and looseness of parts.
1) No electrical discontinuity of 1 s.
2) No damage, crack and looseness of parts.
Vibration
Frequency 10 to 55 Hz, single amplitude :
0.75 mm, 2 h in 3 directions.
Shock
490 m/s2, duration of pulse 11 ms
at 3 times for 3 both axial directions.
ENVIRONMENTAL CHARACTERISTICS
Damp Heat
Exposed at 40 ± 2 C, 90 to 95 %, 96 h.
1) Contact Resistance: 20 m MAX.
×
×
-
-
(Steady state)
Rapid Change of
Temperature
2) Insulation Resistance: 1000 M MIN.
3) No damage, crack and looseness of parts.
Temperature
-55 → +5 TO +35 → +85 → +5 TO +35 C
Time
30 → 10 TO 15 → 30 → 10 TO 15 min.
Under 5 cycles.
Corrosion salt mist
Sulphur Dioxide
Exposed in 5 % salt water spray for 48 h.
1) Contact Resistance: 20 m MAX.
2) No heavy corrosion.
×
×
-
-
Exposed in 10 PPM FOR 96 h.
(Test standard: JEIDA 39)
Resistance to
Soldering Heat
Reflow soldering :250 C MAX,
220 C MIN, for 60 s MAX
No deformation of case of excessive
looseness of the terminals.
×
-
Soldering irons : 360C FOR 5 s MAX.
×
×
-
-
Solderability
Soldered at solder temperature, 245 ± 3 C,
for immersion duration, 3 s.
A new uniform coating of solder shall cover a
minimum of 95 % of the surface
being immersed.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
HR.NAGAYASU
CHECKED
DATE
1
△
1
DIS-F-00004353
HT.YAMAGUCHI
HS.OKAWA
20190301
20050723
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
(1)TEMPERATURE RISE INCLUDED WHEN ENERGIZED.
(2)THIS STORAGE INDICATES A LONG-TERM STORAGE STATE
FOR THE UNUSED PRODUCT BEFORE THE BOARD MOUNTED.
HS.OZAWA
TH.NODA
20050723
20050723
20050723
Unless otherwise specified, refer to IEC-60512.
1
△
Clerical corrections.
AK.SUZUKAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELCX-082599-71-21
A3-*PA-2SV(71)
DRAWING NO.
PART NO.
SPECIFICATION SHEET
1
△
1/1
HIROSE ELECTRIC CO., LTD.
CODE NO.
CL621
FORM HD0011-2-1