A165S/W
Model Number Structure
Model Number Legend..... The model numbers used to order sets of Units are illustrated below. One set comprises the Selector, Lamp
(lighted models only), and Switch.
For information on combinations, refer to Ordering Information on page 3.
(1)
(2) (3) (4)
(5)
(6)
A 1 6 5 W - A 2 A R - 2 4 D - 1
(6) Contact Configuration
Symbol Type
Terminal
1
SPDT
DPDT
SPDT
DPDT
Solder terminal
PCB terminal
2
(1) Lighted/
Non-lighted
1P
2P
2S
Symbol
Type
Non-
lighted
DPDT Screw-less Clamp
S
Note: 1. Only DPDT contacts are available with
3-notch models and Screw-less Clamp
models.
W
Lighted
(4) Color of Selector
(3) Number of Notches/
Resetting Method
2. PCB terminals are available only with
2-notch models.
Symbol
Color
(2) Shape of
Selector
No. of
notches
Reset
Black
(non-lighted
models only)
Symbol
2M
(5) Light Source
No
symbol
method
Symbol
Shape
Rectan-
gular
Symbol
No symbol
24D
Type
Manual
R
G
Y
Red
Non-lighted
24-V LED
J
2 notches
3 notches
Automatic
Manual
Green
Yellow
2A
A
T
Square
Round
3M
Voltage Reduction Unit (24-V Built-in LED)
Automatic
3A
Symbol Type Operating voltage
Rated voltage
T1
T2
100/110 VAC/VDC
200/220 VAC/VDC
110 VAC/VDC
220 VAC/VDC
LED
Note: 1. Solder terminals are only available with 100-V models.
2. The Voltage Reduction Unit is not available for models with
PCB terminals.
3. "T2" is available only for the Screw-less Clamp type.
2