Programmable Angle Sensor IC
with Analog and PWM Output
A1330
OPERATING CHARACTERISTICS (continued): Valid over the full operating voltage and ambient temperature ranges,
unless otherwise noted
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Unit[1]
ANALOG OUTPUT CHARACTERISTIC (continued)
Max input angle position; VCC = 5 V,
HIGH_CLAMP = 0
VOUT(MAX)
Output Saturation Voltage
4.65
–
4.75
0.25
–
V
V
0° input angle position; VCC = 5 V,
HIGH_CLAMP = 0
VOUT(MIN)
0.35
OUTPUT CLAMP PROGRAMMING
Valid for Analog or PWM output,
EEPROM programmable
Clamp High[4]
Clamp Low[4]
VCLAMP(H)
VCLAMP(L)
32
5
–
–
95
68
% VCC or DC
% VCC or DC
Valid for Analog or PWM output,
EEPROM programmable
PWM INTERFACE SPECIFICATIONS
PWM Carrier Frequency[4]
Output Current Limit
fPWM
ILIMIT
Programmable, 3 bit field
156.25
1250
29
–
20,000
Hz
mA
kΩ
%
Minimum output, shorted to 5 V
24
4.7
–
34
–
Pull-up Load [5]
RL
PWM Duty Cycle Minimum [4]
PWM Duty Cycle Maximum [4]
MAGNETIC CHARACTERISTICS
Magnetic Field
DPWM(MIN)
DPWM(MAX)
LOW_CLAMP = 0
HIGH_CLAMP = 0
5
–
–
95
–
%
B
Range of input field
–
–
1200
G
ANGLE CHARACTERISTICS
Output[5]
RESANGLE
tANG
–
–
12
25
–
–
bit
µs
Angle Refresh Rate[6]
ANG_AVE = 0
ANG_AVE = 0
–
120
200
0.5
–
µs
Response Time[4]
Temperature Drift
Angle Error
tRESPONSE
ANGLEDRIFT
ERRANG
ANG_AVE = 3
–
–
µs
Angle change from 25°C; TA = 150°C, B = 300 G
Angle change from 25°C; TA = –40°C, B = 300 G
TA = 25°C, ideal magnet alignment, B = 300 G
TA = 150°C, ideal magnet alignment, B = 300 G
–1.8
–
1.8
–
degrees
degrees
degrees
degrees
0.8
–1.1
–1.5
±0.4
±0.5
1.1
1.5
TA = 25°C, B = 300 G, no internal filtering,
target rpm = 0, 3 sigma, PWM output
–
–
–
±0.6
±0.75
±0.5
–
–
–
degrees
degrees
degrees
Angle Noise
NANG
TA = 150°C, B = 300 G, no internal filtering,
target rpm = 0, 3 sigma, PWM output
B = 300 G, typical angle drift observed
following AEC-Q100 qualification testing
Angle Drift Over Lifetime [7]
ANGLEDRIFT_LIFE
[1] 1 G (gauss) = 0.1 mT (millitesla).
Angular Position
(%)
[2] Operation guaranteed down to 4.5 V, once VCC has risen above 4.65 V.
[3] At power-on, the sensor IC will not respond to commands until VCC rises above VUVLO(H). After that,
the sensor IC will perform and respond normally until VCC drops below VUVLO(L)
.
Transducer Output
[4] Parameter is not guaranteed at final test. Values for this characteristic are determined by design.
[5] RESANGLE represents the number of bits of internal angle information available.
[6] The rate at which a new angle reading will be ready.
50
0
[7] Maximum of 1.0 degree increase in angle error observed following AEC-Q100 stress.
Response Time, t
RESPONSE
t
Definition of Response Time
6
Allegro MicroSystems, LLC
955 Perimeter Road
Manchester, NH 03103-3353 U.S.A.
www.allegromicro.com