A1321/A1322/A1323
Ratiometric Linear Hall Effect Sensor for High-Temperature Operation
DEVICE CHARACTERISTICS1 over operating temperature (TA) range, unless otherwise noted
Characteristic
Symbol
Test Conditions
Min.
Typ.2
Max.
Units
Electrical Characteristics; VCC = 5 V, unless otherwise noted
Supply Voltage
Supply Current
Quiescent Voltage
Vcc(op)
Icc
Operating; Tj < 165°C
B = 0, Iout = 0
4.5
5.0
5.6
2.5
4.7
0.2
–1.5
8.3
30
5.5
V
mA
V
–
8
Vout(q)
Vout(H)
Vout(L)
Iout(LM)
VZ
B = 0, TA = 25ºC, Iout = 1 mA
B = +X, Iout = –1 mA
B = –X, Iout = 1 mA
B = –X, Vout → 0
2.425
2.575
–
–
–
–
–
–
–
–
V
Output Voltage3
V
Output Source Current Limit3
Supply Zener Clamp Voltage
Output Bandwidth
–1.0
6
mA
V
I
cc
= 11 mA = Icc(max) + 3
BW
–
kHz
kHz
Clock Frequency
fC
–
150
Output Characteristics; over VCC range, unless otherwise noted
A1321; Cbypass = 0.1 µF, no load
–
–
–
–
40
25
20
3
mV
mV
mV
Ω
Noise, Peak-to-Peak4
VN
A1322; Cbypass = 0.1 µF, no load
A1323; Cbypass = 0.1 µF, no load
–
–
Output Resistance
Rout
RL
I
out ≤ ±1 mA
–
1.5
–
Output Load Resistance
Output Load Capacitance
Iout ≤ ±1 mA, VOUT to GND
4.7
–
–
kΩ
nF
CL
VOUT to GND
–
10
1 Negative current is defined as conventional current coming out of (sourced from) the specified device terminal.
2 Typical data is at TA = 25°C. They are for initial design estimations only, and assume optimum manufacturing and application
conditions. Performance may vary for individual units, within the specified maximum and minimum limits.
3 In these tests, the vector X is intended to represent positive and negative fields sufficient to swing the output driver between fully OFF
and saturated (ON), respectively. It is NOT intended to indicate a range of linear operation.
4 Noise specification includes both digital and analog noise.
Allegro MicroSystems, Inc.
3
115 Northeast Cutoff, Box 15036
A1321-DS Rev. 3
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com