A1321, A1322,
and A1323
Ratiometric Linear Hall Effect Sensor
for High-Temperature Operation
MAGNETIC CHARACTERISTICS1,2 over operating temperature range, TA; VCC = 5 V, Iout = –1 mA; unless otherwise noted
Characteristics
Symbol
Test Condition
Min
Typ3
5.000
3.125
2.500
Max
5.250
3.281
2.625
Units4
mV/G
mV/G
mV/G
A1321; TA = 25ºC
A1322; TA = 25ºC
A1323; TA = 25ºC
4.750
2.969
2.375
Sensitivity5
Sens
Delta Vout(q) as a func-
tion of temperature
Vout(q)(ΔT)
Defined in terms of magnetic flux density, B
–
–
±10
G
Ratiometry, Vout(q)
Ratiometry, Sens
Positive Linearity
Negative Linearity
Symmetry
Vout(q)(ΔV)
ΔSens(ΔV)
Lin+
–
–
–
–
–
–
–
–
–
–
±1.5
±1.5
±1.5
±1.5
±1.5
%
%
%
%
%
Lin–
Sym
UA Package
Delta Sens at TA = max5 ΔSens(TAmax) From hot to room temperature
Delta Sens at TA = min5 ΔSens(TAmin) From cold to room temperature
–2.5
–6
–
–
–
1
7.5
4
%
%
%
Sensitivity Drift6
SensDrift
TA = 25°C; after temperature cycling and over time
2
LH Package
Delta Sens at TA = max5 ΔSens(TAmax) From hot to room temperature
Delta Sens at TA = min5 ΔSens(TAmin) From cold to room temperature
–5
–3.5
–
–
–
5
8.5
2
%
%
%
Sensitivity Drift6
SensDrift
TA = 25°C; after temperature cycling and over time
0.328
1 Additional information on chracteristics is provided in the section Characteristics Definitions, on the next page.
2 Negative current is defined as conventional current coming out of (sourced from) the specified device terminal.
3 Typical data is at TA = 25°C, except for ΔSens, and at x.x Sens. Typical data are for initial design estimations only, and assume optimum
manufacturing and application conditions. Performance may vary for individual units, within the specified maximum and minimum limits.
In addition, the typical values vary with gain.
4 10 G = 1 millitesla.
5 After 150ºC pre-bake and factory programming.
6 Sensitivity drift is the amount of recovery with time.
Allegro MicroSystems, Inc.
115 Northeast Cutoff, Box 15036
4
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com