生命周期:ActiveReach Compliance Code:unknown
ECCN代码:EAR99HTS代码:8536.50.70.00
Factory Lead Time:12 weeks风险等级:5.79
Is Samacsys:N执行器行程:4.88 mm
执行器类型:ROLLER PLUNGER主体宽度:17.45 mm
主体高度:24.2 mm主体长度或直径:49.2 mm
触点(交流)最大额定R负载:20A@250VAC最大触点电流(交流):20 A
最大触点电流(直流):0.5 A触点(直流)最大额定R负载:.5A@125VDC
最大触点电压(交流):250 V最大触点电压(直流):125 V
电气寿命:500000 Cycle(s)安装特点:PANEL MOUNT
最大操作力:6.18 N最高工作温度:80 °C
最低工作温度:-25 °C最大预行程:1.3 mm
表面贴装:NO开关动作:MOMENTARY
开关功能:SPDT开关类型:SNAP ACTING/LIMIT SWITCH
端接类型:SCREWBase Number Matches:1

A-20GQ21 数据手册

 浏览型号A-20GQ21的Datasheet PDF文件第2页浏览型号A-20GQ21的Datasheet PDF文件第3页浏览型号A-20GQ21的Datasheet PDF文件第4页浏览型号A-20GQ21的Datasheet PDF文件第5页浏览型号A-20GQ21的Datasheet PDF文件第7页浏览型号A-20GQ21的Datasheet PDF文件第8页 
Safety Precautions  
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,  
“Snap Action Switches, Technical Information” for correct use.  
Do not use the switch in locations subject to hot water (greater than  
Precautions for Safe Use  
60°C) or in water vapor.  
Terminal Connection  
Do not use the switch outside the specified temperature and  
atmospheric conditions.  
The permissible ambient temperature depends on the model.  
(Refer to the specifications in this catalog.) Sudden thermal  
changes may cause thermal shock to distort the switch and result  
in faults.  
When soldering lead wires to the Switch, make sure that the capacity  
of the soldering iron is 60 W maximum. Do not take more than 5 s to  
solder any part of the Switch. The characteristics of the Switch will  
deteriorate if a soldering iron with a capacity of more than 60 W is  
applied to any part of the Switch for 5 s or more.  
Operation  
Incorrect  
Correct  
Separate the  
installation lo-  
cation from  
Make sure that the switching frequency or speed is within the  
specified range.  
heat sources.  
1. If the switching speed is extremely slow, the contact may not be  
switched smoothly, which may result in a contact failure or contact  
welding.  
2. If the switching speed is extremely fast, switching shock may  
damage the Switch soon. If the switching frequency is too high,  
the contact may not catch up with the speed.  
Mount a cover if the switch is to be installed in a location where  
worker inattention could result in incorrect operation or accidents.  
The rated permissible switching speed and frequency indicate the  
switching reliability of the Switch.  
Correct  
Incorrect  
The life of a Switch is determined at the specified switching  
speed. The life varies with the switching speed and frequency  
even when they are within the permissible ranges. In order to  
determine the life of a Switch model to be applied to a particular  
use, it is best to conduct an appropriate durability test on some  
samples of the model under actual conditions.  
(preventing malfunctions)  
Subjecting the switch to continuous vibration or shock may result in  
contact failure or faulty operation due to abrasion powder and in  
reduced durability. Excessive vibration or shock will cause the  
contacts to operate malfunction or become damaged. Mount the  
switch in a location that is not subject to vibration or shock and in a  
direction that does not subject the switch to resonance.  
If silver contacts are used with relatively low frequency for a long  
time or are used with microloads, the sulfide coating produced on  
the contact surface will not be broken down and contact faults will  
result. Use a microload switch that uses gold contacts.  
Do not use the switch in atmospheres with high humidity or heat or  
in harmful gases, such as sulfide gas (H2S, SO2), ammonia gas  
(NH3), nitric acid gas (HNO3), or chlorine gas (Cl2). Doing so may  
impair functionality, such as with damage due to contacting faults or  
corrosion.  
Make sure that the actuator travel does not exceed the permissible  
OT position. The operating stroke must be set to 70% to 100% of  
the rated OT.  
Precautions for Correct Use  
Mounting Location  
Do not use the switch alone in atmospheres such as flammable or  
explosive gases. Arcing and heat generation associated with  
switching may cause fires or explosions.  
Switches are generally not constructed with resistance against  
water. Use a protective cover to prevent direct spraying if the switch  
is used in locations subject to splashing or spurting oil or water,  
dust adhering.  
The switch includes contacts. If the switch is used in an atmosphere  
with silicon gas, arc energy may cause silicon oxide (SiO2) to  
accumulate on the contacts and result in contact failure. If there is  
silicon oil, silicon filling, silicon wiring, or other silicon products in  
the vicinity of the switch, use a contact protection circuit to limit  
arcing and remove the source of the silicon gas.  
Incorrect  
Correct  
Terminal box  
Panel-mounting model (A-20GQ@)  
Terminal box  
If a Switch is side-mounted with screws, remove the hexagonal nut  
Install the switch in a location that is not directly subject to debris  
and dust from cutting. The actuator and the switch body must be  
protected from accumulated cutting debris and dirt.  
of the actuator.  
If a Switch is side-mounted and secured with screws, make sure  
that the angle or speed of the actuating object is not excessively  
large or too high, otherwise the Switch may be damaged.  
Incorrect  
Correct  
If a Switch is panel-mounted, pay utmost attention to make sure  
that the actuating speed or OT distance is not excessively high or  
large. Not doing so may damage the Switch.  
24  
Snap Action Switch A  

与A-20GQ21相关器件

型号 品牌 描述 获取价格 数据表
A-20GQ21-B OMRON Snap Action Switch

获取价格

A-20GQ21-B7-K OMRON Snap Action Switch

获取价格

A-20GQ22 OMRON Snap Action Switch

获取价格

A-20GQ22-B OMRON Snap Action Switch

获取价格

A-20GQ22-B7-K OMRON Snap Action Switch

获取价格

A-20GQ-B OMRON Snap Action Switch

获取价格