74HC4050-Q100
Nexperia
Hex non-inverting HIGH-to-LOW level shifter
100 Ω
input
to logic
circuit
polysilicon
resistor
D1
GND
001aan375
Fig 6. Input protection for the 74HC4050-Q100
8. Recommended operating conditions
Table 5.
Recommended operating conditions
Voltages are referenced to GND (ground = 0 V)
Symbol
VCC
Parameter
Conditions
Min
Typ
Max
6.0
15
Unit
V
supply voltage
2.0
5.0
VI
input voltage
0
-
V
VO
output voltage
0
-
VCC
+125
625
139
83
V
Tamb
t/V
ambient temperature
input transition rise and fall rate
40
+25
C
VCC = 2.0 V; VI = 2.0 V
VCC = 4.5 V; VI = 4.5 V
VCC = 6.0 V; VI = 6.0 V
-
-
-
-
ns/V
ns/V
ns/V
ns/V
ns/V
1.67
-
-
-
VCC = 6.0 V; VI = 10.0 V -
VCC = 6.0 V; VI = 15.0 V -
81
83
9. Static characteristics
Table 6.
Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Tamb = 25 C
Min Typ Max
Tamb = 40 C to Tamb = 40 C to Unit
+85 C +125 C
Min
Max
-
Min
Max
-
VIH
HIGH-level
VCC = 2.0 V
1.5
1.3
2.4
3.1
0.7
-
-
1.5
1.5
V
V
V
V
V
V
input voltage
VCC = 4.5 V
3.15
3.15
-
3.15
-
VCC = 6.0 V
4.2
-
4.2
-
4.2
-
VIL
LOW-level
VCC = 2.0 V
-
-
-
0.5
-
-
-
0.5
1.35
1.8
-
-
-
0.5
1.35
1.8
input voltage
VCC = 4.5 V
1.8 1.35
VCC = 6.0 V
2.3
1.8
VOH
HIGH-level
VI = VIH or VIL
output voltage
IO = 20 A; VCC = 2.0 V
IO = 20 A; VCC = 4.5 V
IO = 20 A; VCC = 6.0 V
1.9
4.4
5.9
2.0
4.5
6.0
-
-
-
-
-
-
1.9
4.4
-
-
-
-
-
1.9
4.4
5.9
3.7
5.2
-
-
-
-
-
V
V
V
V
V
5.9
IO = 4.0 mA; VCC = 4.5 V 3.98
IO = 5.2 mA; VCC = 6.0 V 5.48
3.84
5.34
-
74HC4050_Q100
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 1 — 30 January 2013
4 of 13