SCAS133 − D3609, JULY 1990 − REVISED APRIL 1993
†
logic symbol
logic diagram (positive logic)
28
28
GBA
CEBA
LEAB
GAB
1 EN3
G1
GBA
1
1
27
15
14
16
CEBA
1C5
2 EN4
G2
27
LEBA
CEAB
LEAB
15
GAB
2C6
14
2
26
CEAB
B1
A1
3
5D
16
6D
4
LEAB
3
25
24
23
20
19
18
17
B2
B3
B4
B5
B6
B7
B8
A2
A3
A4
A5
A6
A7
A8
2
C1
1D
4
A1
26
B1
5
10
11
12
13
C1
1D
To Seven Other Transceivers
†
This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
‡
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
CC
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to V
+ 0.5 V
+ 0.5 V
I
CC
CC
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to V
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
IK
I
I
CC
Output clamp current, I
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
OK
O O CC
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
Continuous current through V
O
O
CC
CC
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 mA
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
recommended operating conditions
MIN NOM
MAX
UNIT
V
V
V
V
V
V
Supply voltage
4.5
2
5
5.5
CC
IH
IL
High-level input voltage
Low-level input voltage
Input voltage
V
0.8
V
0
0
V
V
V
I
CC
Output voltage
V
O
CC
I
I
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
−24
24
mA
mA
ns/V
°C
OH
OL
Dt/Dv
0
10
T
− 40
85
A
2−2