60ACMEB Series
60W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
60 Watt
Universal input: 90~264VAC
Regulated output, low ripple
and noise
High efficiency up to 88%
Plastic case, meets UL94V-0
Short circuit protection (SCP)
Output power protection (OPP)
Over voltage protection (OVP)
Meet EN60950, UL60950
Mounting: PCB Mounting &
Chassis Mounting with Screw
Terminals
The 60ACMEB series is a compact size power converter offered by
Gaptec. It features universal input voltage, taking both DC and AC input
voltage, low power consumption, high efficiency, high reliability, safer
isolation. It offers good EMC performance, meets IEC/EN61000-4,
CISPR22/EN55022, UL60950 and EN60950 standards, and is widely used
in medical instrumentation and critical applications in commercial and
industrial electronic equipment.
Meets EN60601-1, ANSI/
AAMI ES60601-1 standards
(2xMOOP)
UL 60950-1 (pending)
(pending)
Approval
Model*
Power
[W]
Output voltage
[V]
Output current
[mA, max]
Capacitive Load
[µF, max]
Efficiency
[@230VAC, %, typ]
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
60ACMEB_05S4
60ACMEB_09S4
60ACMEB_12S4
60ACMEB_15S4
60ACMEB_24S4
60
60
60
60
60
5.1
9
10000
6666
5000
4000
2500
10000
5000
5000
4000
2000
86
87
88
86
87
12
15
24
* Add suffix CM for Chassis mounting with screw terminals (f.ex. 60ACMEB_05S4CM), see different package measurements.
Add suffix DR for Din-Rail mounting (f.ex. 60ACMEB_05S4DR).
Input specifications
Output specifications
Item
Input voltage range
90-264 VAC; 120-370 VDC
Test conditions
Min Typ
Max
Units
“ N ” to DC “ + “ ; “L ” to DC “ - “
Output wattage
• 60ACMEB_05S4
• Others
51
60
W
W
Input frequency
Input current
47~440Hz
115VAC
• 1.5A (max)
230VAC
• 1A (max)
Output voltage
accuracy
Full load
2
%
%
%
Inrush current
115VAC
230VAC
Line regulation
Load regulation
0.5
(<2ms, cold start)
• 55A (typ)
• 95A (typ)
1% to 100% load
• 60ACMEB_05S4/
60ACMEB_09S4
• Others
Leakage current
< 0.1mA/264VAC (touch current)
• 3.15A • slow-blow
1.5
1
Recommended external
fuse
%
Ripple & noise*
Hold-up time
• 60ACMEB_05S4/
60ACMEB_09S4
• Others
100
mV
1% of Vout
10 ms
Protection specifications
full load
Short circuit
protection
Protection type:
Automatic recovery
* Measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
Over-voltage
protection
Protection type:
Zener diode clamp
Note:
Over-power
protection
Protection type:
Hiccup model, auto recovery
1. This product is not designed for use in critical life support systems, equipment
used in hazardous environment, nuclear control systems or other such
applications which necessitate specific safety and regulatory standards other
the ones listed in this datasheet.
2. Safety approvals cover frequency 47-63 Hz.
Example:
3. That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
4. It‘s recommended to add Varistor 14S471K at L / N input side in parallel.
5. All specifications valid at normal input voltage, full load and +25°C after warm-
up time unless otherwise stated.
60ACMEB_05S4
60= 60Watt; AC= AC-DC; MEB= series; 5Vout; S= Single Output;
4= 4kVAC
Page 1 of 4
60ACMEB – Rev. 2017-1.0
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG