ELECTRICAL SPECIFICATIONS
DAC2812S
DAC2812S H/E
DAC2812S
Group A
Subgroup
Units
Parameter
Test Conditions 1
Typ.
Max.
Min.
Typ.
Max.
Min.
VDC
VDC
mA
mA
mA
mA
mVrms
mVrms
mAp-p
mAp-p
mV
mV
mV
mV
%
12.0
12.1
12.24
-
11.85
12.0
12.15
1
2,3
1
11.9
Output Voltage
-
-
-
-
11.76
-
417
-
-
417
11V≤VIN≤50V
16V≤VIN≤40V
-
-
-
-
-
2,3
1
417
Output Current 2
-
-
450
-
-
450
-
-
-
-
-
60
-
2,3
1
450
15
60
-
15
-
BW=10KHz to 2MHz
Output Voltage Ripple
-
100
125
200
25
-
-
2,3
1
-
76
-
76
125
-
-
BW=10KHz to 2MHz
LIN=2µH
Input Current Ripple
Line Regulation
2
-
-
-
2,3
1
-
5
-
5
30
-
-
VIN=16, 28 and 40 VDC
IOUT=0, 208 and 417mA
VIN=16, 28 and 40 VDC
IOUT=0, 208 and 417mA
-
50
-
-
2,3
1
-
5
25
-
5
30
-
-
Load Regulation
-
50
-
-
2,3
1
-
67
-
62
67
-
62
Efficiency
%
-
-
-
-
-
2,3
4
60
mV
mV
µS
350
500
700
200
200
500
500
200
200
200
200
60
-
350
500
-
-
IOUT=208mA to/from 417mA
Transition TIme=30µS
IOUT=208mA to/from 417mA
Transition TIme=30µS
VIN=16V to/from 40V
Transition Time=30µS
VIN=16V to/from 40V
Transition Time=30µS
Step Load Response
Step Load Recovery
Step Line Response 2
-
-
-
5,6
4
-
80
-
80
200
-
-
µS
-
-
-
5,6
4
-
mV
mV
µS
200
-
200
500
-
-
-
-
-
5,6
4
-
90
-
90
200
-
-
Step Line Recovery
Start Up Overshoot
Start Up Delay
2
µS
-
-
-
5,6
4
-
mV
mV
mS
mS
µS
0
200
-
-
0
-
-
5,6
4
-
-
-
40
60
-
-
40
-
-
5,6
4
-
-
60
-
250
500
-
-
-
250
500
500
60
-
-
Shutdown Delay 2
Shutdown Recovery
Input Voltage Range
µS
-
5,6
-
-
2
mS
V
40
60
40
50
50
2.5
300
-
-
40
-
-
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1
16
11
-
-
40
16
11
-
POUT=5.4W MAX.
POUT=5W MAX.
2
V
-
35
1.25
-
-
35
1.25
-
50
mA
mA
µF
50
Enabled, IOUT=0mA
Quiescent Current
-
2.5
300
-
-
Disabled IOUT=0mA
2
-
-
No Effect on DC Performance
Input to output or any pin to case @ 500V
Capacitive Load
MΩ
A
-
100
0.50
375
10
-
100
0.50
375
10
Isolation
1.1
400
-
1.8
425
-
7
1
1.1
400
-
1.8
425
-
Short Circuit Current Limit
Switching Frequency
KHz
%
4
1
RPOT=50KΩ
VOUT Adjustment Range
NOTES:
1 +VIN = 28V, IOUT = 417mA, TA=TC=25°C unless otherwise specified.
2 Guaranteed by design but not tested. Typical parameters are representative of actual device performance but are for reference only.
3 Industrial grade and "E" suffix devices shall be tested to subgroups 1 and 4 unless otherwise specified.
4 Military grade devices ("H" suffix) shall be 100% tested to subgroups 1, 2, 3 and 4.
5 Subgroups 5 and 6 testing available upon request.
6 Subgroup 1, 4 TA=TC=+25°C
2, 5 TA=TC=+125°C
3, 6 TA=TC= -55°C
7 Device has internal shutdown feature that pulses the output with a low duty cycle during faults.
8 Consult DSCC SMD for electrical parameters for devices purchased as such.
3