ELECTRICAL SPECIFICATIONS
DHC2805S
DHC2805S H/E
DHC2805S
Group A
Subgroup
Units
Test Conditions 1
Parameter
8
Typ.
Max.
Min.
Typ.
Max.
Min.
VDC
VDC
mA
mA
mA
mA
mVp-p
mVp-p
mAp-p
mAp-p
mV
mV
mV
mV
%
5.00
5.10
1
2,3
1
4.95
5.00
5.05
5.20
1200
1200
1500
1500
190
475
200
200
15
4.90
Output Voltage
-
-
4.80
-
-
-
1200
120
-
120
12V≤VIN≤50V
16V≤VIN≤50V
-
-
2,3
1
120
-
-
Output Current 2
-
1500
120
-
120
-
-
2,3
1
120
-
-
75
190
-
75
-
BW=10KHz to 2MHz
BW=10KHz to 2MHz
VIN=16V to 40V
Output Voltage Ripple
-
-
2,3
1
-
-
-
100
225
-
100
-
Input Current Ripple
Line Regulation
2
-
-
2,3
1
-
-
-
6
20
-
6
-
-
-
2,3
1
-
-
50
-
VIN=16V, 28V and 40V
IOUT=0A, 0.5A and 1A
10
30
-
10
25
-
Load Regulation
-
-
2,3
1
-
-
50
-
70
-
-
64
70
-
64
Efficiency
%
-
2,3
4
62
-
-
-
mV
mV
µS
IOUT=500mA to/from 1000mA
Transition TIme=30µS
IOUT=500mA to/from 1000mA
Transition TIme=30µS
VIN=16V to/from 40V
Transition Time=30µS
VIN=16V to/from 40V
Transition Time=30µS
300
500
-
-
300
500
750
300
300
500
500
500
500
200
200
50
-
Step Load Response
Step Load Recovery
Step Line Response 2
-
5,6
4
-
-
-
90
300
-
-
90
-
µS
-
5,6
4
-
-
-
mV
mV
µS
160
500
-
-
160
-
-
5,6
4
-
-
-
140
500
-
-
140
-
Step Line Recovery
Start Up Overshoot
Start Up Delay
2
µS
-
5,6
4
-
-
-
mV
mV
mS
mS
µS
0
200
-
-
0
-
IOUT=1A
-
5,6
4
-
0
-
30
50
-
-
-
30
-
-
IOUT=0A and 1A
-
5,6
4
-
50
220
500
-
-
220
500
500
-
-
Shutdown Delay 2
Shutdown Recovery
µS
-
5,6
-
-
-
-
2
mS
V
60
-
-
60
-
POUT=6W MAX.
POUT=5W MAX.
-
50
50
50
45
5
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1,2,3
1
12
11
10
-
-
50
12
11
10
-
Input Voltage Range
V
-
2
-
50
V
POUT=2.5W MAX.
-
35
2
-
35
2
50
mA
mA
µF
Enabled, IOUT=0mA
40
Quiescent Current
Disabled IOUT=0mA
-
5
-
2
Capacitive Load
Isolation
No Effect on DC Performance
Input to output or any pin to case @ 500V
-
300
-
-
-
300
-
-
MΩ
A
-
100
1.6
375
10
-
100
1.5
350
10
Short Circuit Current Limit
Switching Frequency
7
1.9
400
-
2.3
450
-
1
1.9
400
-
2.2
425
-
KHz
%
4
VOUT Adjustment Range
RPOT=50KΩ
1
NOTES:
1 +VIN = 28V, IOUT = 1.8A for DHC2803S, IOUT = 1.0A for DHC2805S, TA=TC=25°C unless otherwise specified.
2 Guaranteed by design but not tested. Typical parameters are representative of actual device performance but are for reference only.
3 Industrial grade and "E" suffix devices shall be tested to subgroups 1 and 4 unless otherwise specified.
4 Military grade devices ("H" suffix) shall be 100% tested to subgroups 1, 2, 3 and 4.
5 Subgroups 5 and 6 testing available upon request.
6 Subgroup 1, 4 TA=TC=+25°C
2, 5 TA=TC=+125°C
3, 6 TA=TC= -55°C
7 Device has internal shutdown feature that pulses the output with a low duty cycle during faults.
8 Refer to DSCC SMD for electrical specifications for devices purchased as such.
4