SN55LBC175
QUADRUPLE LOW-POWER DIFFERENTIAL LINE RECEIVER
SGLS083A – MARCH 1995 – REVISED JUNE 2000
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7 V
CC
Input voltage, A or B inputs, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 V
Differential input voltage, V (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 V
I
ID
Data and control voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7 V
Continuous total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
A
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to GND.
2. Differential input voltage is measured at the noninverting input with respect to the corresponding inverting input.
DISSIPATION RATING TABLE
T
≤ 25°C
DERATING FACTOR
T = 125°C
A
POWER RATING
A
PACKAGE
POWER RATING
ABOVE T = 25°C
A
FK
J
1375 mW
11.0 mW/°C
11.0 mW/°C
8.0 mW/°C
275 mW
1375 mW
275 mW
W
1000 mW
200 mW
recommended operating conditions
MIN NOM
4.75
MAX
5.25
12
UNIT
V
Supply voltage, V
CC
5
Common-mode input voltage, V
IC
–7
V
Differential input voltage, V
±6
V
ID
High-level input voltage, V
IH
2
V
EN inputs
Low-level input voltage, V
0.8
–8
V
IL
High-level output current, I
mA
mA
°C
OH
OL
Low-level output current, I
16
Operating free-air temperature, T
–55
125
A
3