SN55LBC172
QUADRUPLE LOW-POWER DIFFERENTIAL LINE DRIVER
SGLS084C – MARCH 1995 – REVISED JANUARY 2003
†
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage range, V
Output voltage range, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –10 V to 15 V
CC
O
Input voltage range, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7 V
I
‡
Continuous power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally limited
Operating free-air temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
A
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
†
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The maximum operating junction temperature is internally limited. Use the dissipation rating table to operate below this temperature.
NOTE 1: All voltage values are with respect to GND.
DISSIPATION RATING TABLE
≤ 25°C DERATING FACTOR
T
A
T = 125°C
A
POWER RATING
PACKAGE
POWER RATING
ABOVE T =125°C
A
FK
J
1375 mW
11.0 mW/°C
11.0 mW/°C
8.0 mW/°C
275 mW
1375 mW
275 mW
W
1000 mW
200 mW
recommended operating conditions
MIN NOM
4.75
MAX
UNIT
Supply voltage, V
CC
5
5.25
V
V
V
High-level input voltage, V
IH
2
Low-level input voltage, V
0.8
12
IL
Output voltage at any bus terminal (separately or common mode), V
Y or Z
V
O
–7
High-level output current, I
Y or Z
Y or Z
–60
60
mA
mA
OH
Low-level output current, I
OL
Continuous total power dissipation
Operating free-air temperature, T
See Dissipation Rating Table
–55 125 °C
A
4