54AC
TA =
VCC
(V)
Symbol
Parameter
Units
Conditions
−55°C to +125°C
Guaranteed Limits
IOZ
Maximum
VI (OE) = VIL, VIH
VI = VCC, VGND
TRI-STATE
Current
5.5
±5.0
μA
VO = VCC, GND
VOLD = 1.65V Max
VOHD = 3.85V Min
IOLD
IOHD
(Note 3) Minimum
Dynamic Output
Current
5.5
5.5
50
mA
mA
−50
ICC
Maximum Quiescent
Supply Current
VIN = VCC
or GND
5.5
80.0
μA
Note 2: All outputs loaded; thresholds on input associated with output under test.
Note 3: Maximum test duration 2.0 ms, one output loaded at a time.
Note 4: IIN and ICC @ 3.0V are guaranteed to be less than or equal to the respective limit @ 5.5V VCC
Note 5: ICC for 54AC @ 25°C is identical to 74AC @ 25°C.
.
DC Characteristics for 'ACT Family Devices
54ACT
VCC
(V)
TA =
Symbol
Parameter
Units
Conditions
−55°C to +125°C
Guaranteed Limits
VIH
Minimum High Level
4.5
5.5
4.5
5.5
4.5
5.5
2.0
2.0
0.8
0.8
4.4
5.4
VOUT = 0.1V
or VCC − 0.1V
VOUT = 0.1V
or VCC − 0.1V
V
V
V
Input Voltage
VIL
Maximum Low Level
Input Voltage
VOH
Minimum High Level
Output Voltage
IOUT = −50 μA
(Note 6)
VIN = VIL or VIH
4.5
5.5
4.5
5.5
3.70
4.70
0.1
IOH
−24 mA
−24 mA
V
V
VOL
Maximum Low Level
Output Voltage
IOUT = 50 μA
0.1
(Note 6)
VIN = VIL or VIH
4.5
5.5
5.5
0.50
0.50
±1.0
IOL
24 mA
24 mA
V
IIN
Maximum Input Leakage Current
Maximum TRI-STATE
Current
VI = VCC, GND
VI = VIL, VIH
μA
μA
IOZ
5.5
±5.0
VO = VCC, GND
VI = VCC − 2.1V
VOLD = 1.65V Max
VOHD = 3.85V Min
ICCT
IOLD
IOHD
Maximum ICC/Input
5.5
5.5
5.5
1.6
50
mA
mA
mA
(Note 7) Minimum
Dynamic Output
Current
−50
ICC
Maximum Quiescent
Supply Current
VIN = VCC
or GND
5.5
80.0
μA
Note 6: All outputs loaded; thresholds on input associated with output under test.
Note 7: Maximum test duration 2.0 ms, one output loaded at a time.
Note 8: ICC for 54ACT @ 25°C is identical to 74ACT @ 25°C.
www.national.com
4
100282 Version 3 Revision 1 Print Date/Time: 2011/07/29 21:07:23