C . Pulse Width Test
Transmitter output
DUT output pulse
600ms 600ms
Twl
Twh
V0h
V0l
Application Circuit
100W*)
Vcc (+5V)
3
4.7mF *)
MIM-5xx3V1
>10kW
optional
MIE-544A2
mC
1
2
GND
*) recommended to suppress power supply disturbances
CHARACTERISTIC CURVES (TA=25oC)
900
800
700
600
500
400
1.8
Burst length * 600ms, cycle = 1.2ms
tpw: Average value of output from start
of signal input to 60th pulse
1.6
1.4
1.2
1.0
Input Level VIN (mVP-P
)
0.1
1
10
Input Level (mVp-p
100
1000
6
3
4
5
7
)
Supply Voltage Vcc (V)
INPUT LEVEL vs.OUTPUT PULSE WIDTH
SUPPLY VOLTAGE vs. SUPPLY CURRENT
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
REV: A1
Unity Opto Technology Co., Ltd.
07/08/2003