Interlock Switches
Guard Locking Switches
Spartan
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119, IEC/
EN60947-5-1, ANSI B11.19, AS4024.1
Category
Approvals
Cat. 1 Device per EN954-1
Dual channel interlocks suitable for
Cat. 3 or 4 systems
CE marked for all applicable directives,
cULus and TUV Nord
Safety Contact
Utilization Cat.
2 N.C. or 3 N.C. direct opening action
AC 15
AC (Ue) 500V 250V 100V
(le) 1A 2A 5A
DC 250V/0.5A 24V/2A
Maximum Switched Current/ 500V/500VA
Volt/Load
Description
Thermal Current (lth)
Min Current
10A
The Spartan is a positive mode, tongue operated guard locking
interlock switch that locks a machine guard closed until power is
isolated and ensures that it remains isolated while the guard is open.
It is available in two contact configurations: two safety (N.C.)
contacts and one auxiliary (N.O.) contact or three safety (N.C.)
contacts. The Spartan head has two entry slots and it can be rotated
to provide four actuator entry points. A blanking plug is provided to
seal the unused slot.
5V 5mA DC
Safety Contact Gap
Rtd. Insulation Voltage
Rtd. Impulse withstand Volt
Auxiliary Contacts
Pollution Degree ➊
Max Actuation Speed
Max Actuation Frequency
Case Material
>2mm
500V
2500V
1 N.O.
3
The guard may only be opened when a signal is applied to the
Spartan’s internal solenoid which releases the lock mechanism.
Therefore the Spartan is ideal for machines which do not stop
immediately or where premature interruption of the machine could
cause damage to tooling and components or cause an additional
hazard.
160mm/second (6.3 in/sec)
1 cycle/second
UL Approved glass filled polyester
Stainless steel
IP 67
Actuator Material
Protection
Conduit Entry
1 x M20 or quick disconnect style
-20°C to 60°C (-4°F to +140°F)
2 x M5
The locking mechanism withstands forces up to of 1200N (270lbs.)
and an LED provides visual indication of switch status.
Operating Temperature
Fixing
A catch kit with actuator alignment is also supplied to relieve stress
on the locking solenoid and to protect the unit from actuator
damage due to poor guard alignment. Manual release points with
security screws or special key allow the locked Spartan to be released
in the event of total power failure on a machine.
Mounting
Any position
Mechanical Life
1,000,000 operations
1,000,000 operations
260g (0.57 lb)
Red
Electrical Life
Weight
Colour
Features
Max Holding Force
Min Operating Radius
LED Indication
1200N (270lbs)
175mm (6.9in)
Solenoid monitor LED
•
•
•
•
•
Power to release
Lid mounted status indication
High locking force—1200N (270lbs.)
2 N.C. & 1 N.O. or 3 N.C.
Power Supply
24V AC/DC, 110V AC, 230V AC
(solenoid)
Rotatable head: 4 possible key entry slots
Solenoid Power
Typically 7W 100% ED
➊ Conductive pollution occurs, or dry, non conductive pollution occurs which
becomes conductive due to condensation.
Typical Applications
Note: Lift-off guards require good alignment when using
tongue actuated interlock switches.
IMPORTANT: It must not be possible to lift the guard
without actuating the interlock. An interlock on either side
may be required.
3-24