Technical specification:
Rated voltage:
4pos
250 V
IEC 61076-2-101
A
Current rating:
IEC 61076-2-101
4 A at 40°C
>=100 M
3/2
Ω
Insulation resistance:
IEC 60512
n
14
Pollution degree:
IEC 60664-1
Degree of protection:
IEC 60529
IP 65, in mated
condition
Temperature range:
IEC 60664-1
+100°C - 30.000 h
+125°C - 8.000 h
+150°C - 2.000 h
Mating cycles:
IEC 60512-9a
>=100
Materials:
n
11
Contact:
CuZn, CuBe
Contact plating:
Contact carrier:
Sealing:
Nickel, gold plated
PBT GF, UL 94
FPM
D
Coupling nut:
Moulding body:
CuZn, nickel plated
Thermoplastic,
elastomere, grey
Installation specification:
A
Recommended
torque:
0,6 Nm
3
2
4
1
Contact assignment:
brown
1
white
2
blue
3
black
4
Part no:
Description:
Length L:
Cable:
43-10480
43-10481
43-10482
43-10483
43-xxxxx
SAL - HT - 12 - RK4 - 2 / S1
SAL - HT - 12 - RK4 - 3 / S1
SAL - HT - 12 - RK4 - 5 / S1
SAL - HT - 12 - RK4 - 10 / S1
2m
3m
5m
10m
x
TPE,
black, 4x0,34mm²
Cable: 781-S13400
D see data sheet cable
SAL - HT - 12 - RK4 - ... / S1
title:
Index: a 28.02.11 VF Ä3909
technical specification changed, part no.
cable in table added, data sheet modified
dim. in mm
Female connector M12x1 axial, HT
date
name
drawn
appd.
08.03.07
08.03.07
Fromm
Mankopf
L <= 4m: L + 40mm
L > 4m: L + 1%
tolerance of cable:
general tolerance:
dwg no:
0
0,0
± 0,50mm
± 0,25mm
R
43K1A083
0,00 ± 0,10mm
THIS DRAWING MAY NOT BE COPIED OR REPRODUCED IN ANY WAY, AND
MAY NOT BE PASSED ON TO A THIRD PARTY WITHOUT WRITTEN PERMISSION.
OWNERSHIP AND COPYRIGHT OF CONEC GmbH
part no:
see table