402 Series Mechanical Details
402L Front View
402L Rear View
1
2
3
4
5
6
7
8 9
10
11
12 13 14 15
1 - HV On/Off Push Buttons (L model only)
8 - HV Output Connector
9 - Ground Stud
10 - Inhibit BNC (L models only)
11 - Cooling Fan
12 - Slave Supply Programming Connector (L models only)
13 - Remote Programming Connector
14 - AC Input Terminal Block
2 - Status Indicator LEDs (L and S models only)
3 - Local/Remote Keyswitch (L model only)
4 - 10-Turn HV Output Control (L models only)
5 - View Set Push Button (L models only)
6 - Output Voltage and Current Displays (L models only)
7 - Power Switch (L and S models only)
15 - Interlock Terminals
Outline Drawings
TO SLAVE
MODEL 402L
STATUS
HV ON
VOLTAGE
ADJUST
10 TURN INC
HV ON
kV
HV OFF
%
INHIBIT
0
10
20
30
40
50
70
80
90
100
110
60
END OF CHARGE
INTERLOCK OPEN
LOAD FAULT
HV OFF
CURRENT
REMOTE
A
OVERTEMP
!
%
0
20
40
60
80
100
120
140
CONTROL
OFF
REMOTE
LOCAL
VIEW SET
POWER
INHIBIT
+
+
N
3
19" / 483mm
17" / 432mm
Chassis slide mounting holes
17" / 432mm
Notes:
1 - Chassis slide mounting pattern matches General Devices CT series or equivalent with 3.875" hole spacing.
2 - Cooling air enters rear of unit and exits at either side. Do not block air vents or cooling fan and allow several inches
of clearance at rear of unit.
3 - Allow 6" bend radius at rear of unit for HV cable.
| 2
402 Series Data Sheet
Trusted • Innovative • Reliable