Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Multipurpose Power Line RFI Filter for Emission Control
V and W Series
UL Recognized
CSA Certified
VDE Approvedꢀ
VV1 / VW1
VV6 / VW6
Both the V and W series are effective to control
emissions in equipment using SCR and T2L circuits
for compliance with FCC Part 15, Subpart J and
EN55022, Level A, down to 150kHz
Specifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
.5 mA
.82 mA
@250 VAC 50 Hz:
Hipot rating (one minute):
Line to Ground:
2250 VDC
1450 VDC
V Series
Line to Line:
• Offers an N = 3 (“T”) Line to Ground impedance to
common mode and an N = 5 “Dbl. Pi”) impedance
for Line to Line differential mode interference
Rated Voltage (max):
250 VAC
50/60 Hz
3 to 20A*
Operating Frequency:
• Designed for susceptibility use when equipment
impedance at RF frequencies is low
Rated Current:
Operating Ambient Temperature Range
(at rated current I ):
-10°C to +40°C
W Series
r
In an ambient temperature (T ) higher than +40°C
a
• Offers an N = 4 (“Dbl. L”) Line to Ground
impedance for common mode and an N=5 (“Dbl.
Pi”) impedance for Line to Line differential mode
interference
the maximum operating current (I ) is calculated as
o
follows: I = I (85-Ta)/45
o
r
Electrical Schematics
• Designed for use when equipment impedance at
RF frequencies is high
V Series
LINE
LOAD
• Two stage construction provides excellent
suppression at high frequencies
Ordering Information
20 V V 6
W Series (3, 6 & 10A)
LINE
LOAD
Input / Output Style
1 – .250 [6.3] spade terminals
6 – Threaded bolt
7 – IEC inlet* (line side)
.250 [6.3] spade terminals
(load side)
W Series (20A)
LINE
LOAD
V or W Series
Leakage current designation
V – Standard
Current Rating
3, 6, 10 or 20A
B20VW7, 20A model tested by Underwriters Laboratories
to US and Canadian requirements and is
VDE approved at 16A, 250VAC
*IEC 60320-1 C20 inlet mates with C19 connector
86
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com