PECL OSCILLATORS
HPL64 PECL OSCILLATORS
6 Pa d SMD Pa cka g e
OUTLINES & DIMENSIONS
FEATURES
·
·
·
·
Ph a se Lock Loop te ch n iq ue
Low-cost PECL outp ut p a cka g e
Jitte r 15p s RMS for n on jitte r-se n sitive a p p lica tion s
Min ia ture 6 p a d SMD p a cka g e h e ig h t 4.7m m
GENERAL SPECIFICATION
Outp ut Wa ve form :
PECL 10K square wave
PLL based
Fre q ue n cy Ra n g e :
Fre q ue n cy Sta b ility:
In p ut Volta g e Vcc
19.440MHz to 200MHz
See table
LVPECL
PECL
+ 3.3V± 5%
See note
See note
+ 5.0V± 5%
OH
Outp ut Volta g e HIGH ‘1’ V
LOW ‘0’ V
Curre n t Con sum p tion :
:
OL
:
See table and note
Loa d :
50W into Vcc-2V
or Thevenin equivalent*
2ns max (20%~ 80%Vcc)
50± 2% typ., 50± 5% max.
(both outputs)
Rise / Fa ll Tim e s:
Duty Cycle :
Jitte r
RMS:
15ps
1 Sig m a :
20ps typical (clock period jitter)
(77.760MHz 5.0V example)
-60dBc @ 10Hz offset
-90dBc @ 100Hz offset
-105dBc @ 1kHz offset
-110dBc @ 10kHz offset
-110dBc @ 100kHz offset
10ms max.
CURRENT CONSUMPTION
SSB Ph a se n oise :
Curre n t Con sum p tion (m A)
+ 3.3
+ 5.0
75mA max excluding load current
95mA max excluding load current
Sta rt-up Tim e :
Ag e in g :
Stora g e Te m p e ra ture :
Tri-sta te Op tion :
Note: Total current consumption is is determined by the
user’s terminating scheme and internal pull-up resistors.
± 2ppm/ year max.
-55° to + 100°C
Disables both outputs when ‘LOW’
Internal pull-up.
* Terminating resistors required on all outputs.)
NOTES
OUTPUT VOLTAGE
Output voltage can be to custom specification or standard at
2.25V min. for + 3.3V supply or 3.95V min. for 5.0V supply.
To achieve necessary logic levels provide terminating scheme
information when ordering or use terminating resistors
recommended by Euroquartz.
ORDER CODE
Sup p ly
HPL64
Sta b ility Cod e
(A to F)
Nom in a l
Fre q ue n cy
Volta g e
Stability Code
A to F or
Package
Style
Nominal
Frequency
‘3’ for + 3.3V
‘5’ for + 5.0V
FREQUENCY STABILITY
Cxx or Ixx
Te m p e ra ture Ra n g e Ord e r Cod e
Sta b ility
(p p m )
0°~ + 70°C
-40°~ + 85°C
EXAMPLE:
± 25
± 50
± 100
A
B
C
D
E
F
5HPL64-A-125.0
This describes HPL64 package PECL, + 5.0Volt supply, ± 25ppm over 0°to
+ 70°C, at frequency of 125.0MHz.
Note: For non-standard frequency stability for commercial temperature
range use the Code’C’ followed by the stability, example ‘C20’ for
± 20ppm over 0° to + 70°C. For industrial temperature range use ‘I’
and the stability, example ‘I20’ for ± 20ppm over -40° to + 85°C.
EUROQUARTZ LIMITED Bla ckn e ll La n e CREWKERNE Som e rse t UK TA18 7HE
Te l: + 44 1460 230000 Fa x: + 44 1460 230001 e m a il: in fo@e uroq ua rtz.co.uk we b : www.e uroq ua rtz.co.uk