Type 381LL/383LL, 105 °C Long Life, Snap-In Aluminum
8,000 Hour Snap-in
Typical Performance Curves
10
20
18
16
14
12
10
8
6000 hr. Performace Curve
8
6
Delta Cap %
DF %
4
DCL (uA)
2
6
4
0
0
2000
4000
6000
2
-2
0
Hours @ Max Temp, Voltage, Ripple
Based on 330uF 250Vdc Endurance Life Test
Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data ꢂcollectively, the “Information”) in
this datasheet or other publication are subject to change. The customer is responsible for checking, confirming and verifying the extent to which
the Information contained in this datasheet or other publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation or responsibility of any kind,
expressed or implied. Statements of suitability for certain applications are based on the knowledge that the Cornell Dubilier company provid-
ing such statements ꢂ“Cornell Dubilier”) has of operating conditions that such Cornell Dubilier company regards as typical for such applications,
but are not intended to constitute any guarantee, warranty or representation regarding any such matter – and Cornell Dubilier specifically and
expressly disclaims any guarantee, warranty or representation concerning the suitability for a specific customer application, use, storage, trans-
portation, or operating environment. The Information is intended for use only by customers who have the requisite experience and capability to
determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by Cornell Dubilier
with reference to the use of any Cornell Dubilier products is given gratis ꢂunless otherwise specified by Cornell Dubilier), and Cornell Dubilier
assumes no obligation or liability for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality
and safety standards regarding the design and manufacturing of its products, in light of the current state of the art, isolated component failures
may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other
safeguards ꢂsuch as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the
failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions
and notes must be observed, the customer should not assume that all safety measures are indicated in such warnings, cautions and notes, or that
other safety measures may not be required.
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800