描述
3.3-V CAN TRANSCEIVERS

230Q1 数据手册

 浏览型号230Q1的Datasheet PDF文件第3页浏览型号230Q1的Datasheet PDF文件第4页浏览型号230Q1的Datasheet PDF文件第5页浏览型号230Q1的Datasheet PDF文件第7页浏览型号230Q1的Datasheet PDF文件第8页浏览型号230Q1的Datasheet PDF文件第9页 
SN65HVD230Q-Q1  
SN65HVD231Q-Q1  
SN65HVD232Q-Q1  
SGLS117C JUNE 2001 REVISED JUNE 2002  
absolute maximum ratings over operating free-air temperature (see Note 1) (unless otherwise  
noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 V to 6 V  
CC  
Voltage range at any bus terminal (CANH or CANL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V to 16 V  
Voltage input range, transient pulse, CANH and CANL, through 100 (see Figure 7) . . . . . . . . . . . . 25 V to 25 V  
Input voltage range, V (D or R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to V  
+ 0.5 V  
I
CC  
Electrostatic discharge: Human body model (see Note 2)  
CANH, CANL and GND . . . . . . . . . . . . . . . . . . 15 kV  
All pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 kV  
Charged-device model (see Note 3) All pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 kV  
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating table  
Storage temperature range, T  
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
stg  
Stresses beyond those listed under absolute maximum ratingsmay cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditionsis not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTES: 1. All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.  
2. Tested in accordance with JEDEC Standard 22, Test Method A114-A.  
3. Tested in accordance with JEDEC Standard 22, Test Method C101.  
DISSIPATION RATING TABLE  
T
25°C  
DERATING FACTOR  
T
= 70°C  
T
= 85°C  
T = 125°C  
A
POWER RATING  
A
A
A
PACKAGE  
POWER RATING  
ABOVE T = 25°C  
POWER RATING  
POWER RATING  
A
D
725 mW  
5.8 mW/°C  
464 mW  
377 mW  
145 mW  
This is the inverse of the junction-to-ambient thermal resistance when board-mounted and with no air flow.  
recommended operating conditions  
PARAMETER  
MIN  
NOM  
MAX  
3.6  
7
UNIT  
V
Supply voltage, V  
CC  
3
§
2  
Voltage at any bus terminal (common mode) V  
IC  
V
Voltage at any bus terminal (separately) V  
2.5  
7.5  
V
I
High-level input voltage, V  
IH  
D, R  
D, R  
2
V
Low-level input voltage, V  
0.8  
6
V
IL  
Differential input voltage, V (see Figure 5)  
6  
V
ID  
V
0
V
V
V
(RS)  
(RS)  
CC  
V
for standby or sleep  
0.75 V  
V
CC  
CC  
Rs wave-shaping resistance  
0
40  
8  
100  
kΩ  
Driver  
High-level output current, I  
mA  
OH  
Receiver  
Driver  
48  
8
Low-level output current, I  
mA  
OL  
Receiver  
Operating free-air temperature, T  
40  
125  
°C  
A
§
The algebraic convention, in which the least positive (most negative) limit is designated as minimum is used in this data sheet.  
6
www.ti.com  

与230Q1相关器件

型号 品牌 描述 获取价格 数据表
230XL037 ETC RIEMEN SYNCHR XL TEILUNG WIRKLAENGE 23

获取价格

231 LITTELFUSE 6.3x32 mm MINIATURE FUSES

获取价格

231 MARL Direct replacement for BA15s

获取价格

23-1 GRAYHILL Momentary Contact 100,000 Cycles of Operation

获取价格

231.SA ETC General Purpose Tweezers

获取价格

231_1 LITTELFUSE 6.3x32 mm MINIATURE FUSES

获取价格