Small size - High voltage – High Capacitance
FEATURES
UPS – DC link – AC/DC motor controls – Power inverters
APPLICATIONS
-40°C to +100°C
Above +85°C applied voltage must be de-rated by 1.5%/°C
Operating Temperature Range
+10% at 1 kHz, 25°C
+5% optional
Capacitance Tolerance
Code
A35
575
630
660
720
750
815
A40
700
770
805
885
910
1000
A45
800
A50
900
A55
1000
1100
1150
1265
1300
1430
A60
1100
1200
1265
1380
1430
1560
A70
1275
1400
1465
1610
1655
1820
85°C
VDC
70°C
880
1000
1035
1150
1170
1300
Surge
Voltage
85°C
Repetitive
920
SVDC
70°C
1010
1040
1140
Non-
repetitive
SVDC
85°C
70°C
Repetitive SVDC: Maximum repetitive voltage for 1 hour Max/Day
Code
VDC
A35
575
240
250
A40
700
285
300
A45
800
315
330
A50
900
350
370
A55
1000
400
A60
1100
420
A70
1275
440
AC Voltage
85°C
70°C
VAC
420
440
460
Dissipation Factor (MAX)
Tan δ (%)
C< 4μF 4μF<C<12μF
12μF<C<20μF 20μF<C<40μF 40μF<C<75μF C>75μF
.06
.08
.11
.14
.17
.2
at 1 kHz and 25°C
Lead spacing
(mm)
Frequency range
ESR Value
ESR
(mΩ)
27.5
37.5
52.5
10kHz - 60kHz
10kHz – 45 kHz
10kHz – 30 kHz
See standard part listing
See standard part listing
See standard part listing
RMS Current
No RMS current is to be applied at temperatures > +95°C
See standard part listing, No ripple current is to be applied when the ambient temperature
is>+95°C
Ripple Current
3000 MΩxuF (10000 MΩxuF typical)
“Not to exceed 3GΩ”
Insulation Resistance
After 1 minute of 100VDC applied between the terminals at 25°C
Self Inductance
<1 nano-Henry per mm of lead spacing and lead length
Capacitance variation <1% MAX after 2 years
Long Term Stability
Terminal to Terminal
Terminal to case
Dielectric Strength
150% of VDC or 150% of VAC
applied for 10 Seconds and 25°C
3KVAC at 50/60 Hz applied between the terminals
and case for 60 Seconds and 25°C