5秒后页面跳转
1GU16 PDF预览

1GU16

更新时间: 2024-02-24 01:43:03
品牌 Logo 应用领域
ALTECH 电路保护
页数 文件大小 规格书
32页 1762K
描述
Thermal Magnetic Circuit Breaker,

1GU16 技术参数

生命周期:ObsoleteReach Compliance Code:unknown
风险等级:5.57电路保护类型:THERMAL MAGNETIC
Base Number Matches:1

1GU16 数据手册

 浏览型号1GU16的Datasheet PDF文件第7页浏览型号1GU16的Datasheet PDF文件第8页浏览型号1GU16的Datasheet PDF文件第9页浏览型号1GU16的Datasheet PDF文件第11页浏览型号1GU16的Datasheet PDF文件第12页浏览型号1GU16的Datasheet PDF文件第13页 
TWO POLE  
THREE POLE  
Basic Dimensions (side view)  
35 mm  
(1.38 in.)  
70mm (2.76 in.)  
2D  
3D  
Rated  
Type/  
Type/  
V-EA-D Trip  
0.3A Through 10A Rated Current  
Current  
Cat. No.  
Approvals  
Cat. No.  
Approvals  
1.13-1.45xIN  
60  
40  
3DU03  
3DU05  
3DU075  
NA  
3DU1  
3DU1.6  
3DU2  
3DU2.5  
3DU3  
3DU3.5  
3DU4  
3DU5  
3DU6  
0.3A  
0.5A  
0.75A  
2DU03  
2DU05  
2DU075  
NA  
2DU1  
2DU1.6  
2DU2  
2DU2.5  
2DU3  
2DU3.5  
2DU4  
2DU5  
2DU6  
U
U
L
L
U
U
L
L
10  
Thermal Overload  
Must Trip< 1 hr = 145% RC  
Must Not Trip> 1 hr = 113% RC  
U
U
L
L
4
0.8A  
1.0A  
1.6A  
2.0A  
2.5A  
3.0A  
3.5A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
1
U
U
L
L
U
U
L
L
10  
4
U
U
L
L
U
U
L
L
U
U
L
L
1
U
U
L
L
0.4  
U
U
L
L
10-1  
U
U
L
L
4x10-2  
U
U
L
L
U
U
3DU8  
3DU10  
NA  
L
10-2  
2DU8  
2DU10  
NA  
L
U
4x10-3  
U
L
L
12A  
10-3  
NA  
12.5A  
13A  
NA  
1
2
3
4
5 6 8 10  
20  
40  
100  
16  
U
U
L
L
3DU13  
3DU15  
3DU16  
3DU20  
3DU25  
3DU30  
3DU32  
3DU40  
3DU50  
3DU60  
3D63  
Multiple of Rated Current  
2DU13  
2DU15  
2DU16  
2DU20  
2DU25  
2DU30  
2DU32  
2DU40  
2DU50  
2DU60  
2D63  
U
U
L
L
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A  
U
U
V-EA-D Trip  
13A Through 63A Rated Current  
L
L
U
U
L
L
1.13-1.45xIN  
60  
40  
U
U
L
L
U
U
L
L
U
U
L
L
10  
Thermal Overload  
Must Trip< 1 hr = 145% RC  
Must Not Trip> 1 hr = 113% RC  
U
U
L
L
4
U
U
L
L
1
U
U
L
L
10  
4
480Y/277VAC  
480Y/277VAC  
1
0.3-60A (RC): 10kA with UL-listed  
RK5 back-up fuse or MCCB  
0.3-60A (RC): 10kA with UL-listed  
RK5 back-up fuse or MCCB  
0.4  
10-1  
0.3-10A (RC): 10kA; 13-60A (RC): 5kA  
no branch circuit protection required  
0.3-10A (RC): 10kA; 13-60A (RC): 5kA  
no branch circuit protection required  
4x10-2  
0.3-63A (RC): 10kA  
0.3-63A (RC): 10kA  
10-2  
4x10-3  
10000 ON/OFF operations  
10000 ON/OFF operations  
40°C (104°F)  
40°C (104°F)  
10-3  
1
2
3
4
5 6 8 10 1620  
40  
100  
5/1.4kg (3.1 lb.)  
4/1.68kg (3.7 lb.)  
Multiple of Rated Current  
DMagnetic Trip Parameters  
Rated current 0.3A to 63A.  
Top: 18-3 AWG; Bottom: 18-2 AWG  
20 lb.in.  
Top: 18-3 AWG; Bottom: 18-2 AWG  
20 lb.in.  
1. Hold for a minimum of 100ms at  
surge of 10 times rated current.  
2. Trip in under 100ms at 16 times  
rated current.  
91.5 mm  
(3.60 in.)  
91.5 mm  
(3.60 in.)  
NB: Trip curves shown comply with North  
American standards. For trip curves  
according to European standards please  
consult Altech.  
35 mm (1.38 in.)  
52.5 mm (2.07 in.)  
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com  
13  

与1GU16相关器件

型号 品牌 描述 获取价格 数据表
1GU3.5 ALTECH Thermal Magnetic Circuit Breaker,

获取价格

1GU42 TAYCHIPST HIGH SPEED RECTIFIER APPLICATION

获取价格

1GU42 TOSHIBA RECTIFIER (HIGH SPEED RECTIFIER APPLICATIONS)

获取价格

1GU42 EIC Fast / Super Fast Recovery Rectifiers

获取价格

1GU42TPA2 TOSHIBA DIODE 1 A, 400 V, SILICON, SIGNAL DIODE, Signal Diode

获取价格

1GU42TPA3 TOSHIBA DIODE 1 A, 400 V, SILICON, SIGNAL DIODE, Signal Diode

获取价格