Datasheet
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
System pitch 5.08 mm (0.200 inch)
BLZP 5.08/12/180 SN BK BX
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-2083
Technical data
System parameters
Conductor connection system
Pitch in mm
Clamping yoke connection
Outgoing direction of conductor
180°
5.08 mm
12
Pitch in inch
0.2 inch
1
No. of poles
No. of rows
Screwdriver blade
Tightening torque, min.
Clamping screw
L1 in mm
0.6 x 3.5
0.4 Nm
M 2.5
Screwdriver blade standard
Tightening torque, max.
Stripping length
L1 in inch
DIN 5264
0.5 Nm
7 mm
55.88 mm
2.2 inch
Electric shock protection to DIN VDE 57 106 Safe from finger touch
Material data
Insulating material
colour chart
CTI
PBT
Colour
black
Similar to RAL 9011
≥ 200
Flammability class UL 94
Contact material
Contact base material
V-0
Copper alloy
Copper alloy
Contact surface
tinned
Connectable conductors
Clamping range, min.
0.13 mm²
Clamping range, max.
4 mm²
Conductor connection cross-section AWG,
min.
Conductor connection cross-section AWG,
max.
AWG 26
0.2 mm²
0.2 mm²
0.2 mm²
AWG 12
4 mm²
Solid, min. H05(07) V-U
Solid, max. H05(07) V-U
Flexible, min. H05(07) V-K
Flexible, max. H05(07) V-K
4 mm²
w. wire end ferrule, DIN 46228 pt 1, min
w. plastic collar ferrule, DIN 46228 pt 4, min.
with wire end ferrule, DIN 46228 pt 1, max. 4 mm²
with plastic collar ferrule, DIN 46228 pt 4,
0.2 mm²
max.
2.5 mm²
Gauge to EN 60999 a x b; ø
2.8 mm x 2.4 mm
DIN IEC rating data
Rated current, min. No. of poles (Tu=20°C) 19 A
Rated current, no. of poles (Tu=40°C), min. 16 A
Rated voltage for overvoltage class/pollution
Rated current, max. No. of poles (Tu=20°C) 15.5 A
Rated current, no. of poles (Tu=40°C), max. 13 A
Rated voltage for overvoltage class/pollution
severity II/2
400 V
severity III/2
320 V
Rated voltage at overvoltage category/
pollution degree III/3
Rated impulse withstand voltage for
overvoltage class/pollution severity II/2
250 V
4 kV
Rated impulse withstand voltage for
overvoltage class/pollution severity III/2
Rated impulse withstand voltage for
overvoltage class/pollution severity III/3
4 kV
4 kV
Short-time withstand current resistance
3 x 1s with 120 A
CSA rating data
Rated voltage (Use group B)
Rated voltage (Use group C)
Rated current (use group D)
Wire cross-section, AWG, max.
300 V
50 V
Rated current (use group B)
Rated voltage (use group D)
Wire cross-section, AWG, min.
10 A
300 V
AWG 26
10 A
AWG 12
UL 1059 rating data
Rated voltage (use group B)
Rated voltage (use group C)
Rated current (use group D)
Wire cross-section, AWG, max.
300 V
50 V
Rated current (use group B)
Rated voltage (use group D)
Wire cross-section, AWG, min.
10 A
300 V
AWG 26
10 A
AWG 12
Creation date June 17, 2010 5:46:49 PM CEST
Last update 03.05.2010 / We reserve the right to make technical changes.