Model 150
Stratum 3, 9x14 mm OCXO
Electrical Specifications
Parameter
Conditions & Remarks
Min
-40
Typical
-
Max
Unit
Operating Conditions
Operating Temperature Range TOP
85
°C
3.135
4.75
3.3
5.0
3.465
5.25
Supply Voltage
VCC: 3.3V or 5.0V
Vdc
Warm-up
Steady State; TA = 25°C
-
-
-
2.7
1
Power Consumption
Load
W
0.7
13.5
15
16.5
pF
Frequency Stability
Frequency
FNOM
10
-
-
-
50
MHz
ppm
Initial Frequency Tolerance
@25°C, at time of shipment
±0.5
Freq. vs Temperature
(See options - Table 1)
-40°C to 85°C (ref to +25C)
-
-
±100
ppb
Freq. vs Supply Voltage
Freq. vs Load
VCC ±5%
-
-
-
-
±50
±50
ppb
ppb
15 pf ±5%
-
-
-
±2
±300
±3
-
-
-
ppb/day
ppb/year
ppm/10 yrs
Freq. vs Time (Aging )
After 30 days of operation
Free run accuracy
All causes – 10 years
1.0 sec
-
-
-
-
±4.6
0.1
ppm
ppb
Short Term Stability (ADEV)
@ 25°C, After 5 mins
referenced to the freq after 1
hour on
Warm-up time
-
-
±500
ppb
- Constant temperature
- Over Ambient temperature
(See options - Table 1)
-
-
-
-
±10
200
ppb
ppb, pk-pk
Holdover Stability (24 hours)
Wander Generation
Meets Stratum 3 MTIE and TDEV requirements per Telcordia GR-1244-CORE (See Table 1)
Output Parameters
-
-
-
-
-
-
0.4
0.4
-
-
VOL
3.3V (LVCMOS)
5.0V (HCMOS)
CMOS Output Levels
Vdc
2.4
3.0
VOH
Rise/Fall Times
Duty Cycle
10% to 90%, 15pf load
@50% of output signal
-
-
5
ns
%
45
50
55
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
-
-
-
-
-
-
-70
-
-
-
-
-
-
-100
-125
-142
-148
-151
Phase Noise
(Typical for 25.0 MHz)
dBc/Hz