140PC...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
(unless otherwise noted VS = 8.00 ±0.01 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
Typ.
Max.
Unit
vacuum gage devices2
differential devices3
141PC01G-PCB
141PC05G-PCB
141PC15G-PCB
141PC30G-PCB
141PC100G-PCB
142PC01D-PCB
142PC05D-PCB
142PC15D-PCB
142PC30D-PCB
142PC100D-PCB
142PC150D-PCB
142PC15A-PCB
142PC30A-PCB
142PC100A-PCB
143PC01D-PCB
143PC03D-PCB
143PC05D-PCB
143PC15D-PCB
-1
-5
0
0
0
0
0
psig
-15
-30
-100
(vacuum)
0
0
0
0
0
0
0
0
0
1
5
15
30
100
150
psid(g)
absolute devices3
15
30
psia
100
pressure/vacuum devices3
-1
-2.5
-5
1
2.5
5
psid(g)
-15
15
Zero pressure offset
141PC.../142PC...-PCB
0.95
1.00
3.50
1.05
143PC...-PCB
3.45
3.55
Full scale span4
141PC.../142PC...-PCB
143PC...-PCB
4.95
2.45
5.00
5.05
2.55
V
2.50
Full scale output
5.90
6.00
1.00
0.1
6.10
Output at lowest specified pressure
143PC...-PCB
Non-linearity and hysteresis (BSL)5
0.5
±3.0
±1.0
Thermal effects6
all 1 psi devices
all others
±1.5
%FSO
Combined offset and span (0 to 70°C)
±0.5
Long term stability7
±0.1
0.1
4.5
Response time (10 to 90%)
Current consumption
ms
mA
Radiated, radio frequency electromagnetic
field immunity (RFI) EN6100-4-3 grade 3,
80 to 1000 MHz,
10
V/m
80 % AMC (1 KHz)
Specification notes:
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
The output signal of all 141PC...-PCB devices is proportional to the vacuum applied to port A, relative to port B, e. g. the
output signal increases when pressure is applied to port B relative to port A.
1.
2.
The output signal of all 142PC...D-PCB and 143PC...D-PCB devices is proportional to the pressure applied to portA, relative
to port B, e.g. the output signal increases when vacuum is applied to port B relative to port A.
3.
Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.
Change in output after one year or 1 million pressure cycles.
4.
5.
6.
7.
2/4
March 2006 / 554
www.sensortechnics.com