Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors
13 mm Series
PRESSURE SENSOR CHARACTERISTICS (all devices)
Environmental specifications
Compensated temperature range
Operating temperature range
Storage temperature range
Vibration
0 °C to 82 °C [32 °F to 180 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
10 G at 20 Hz to 2000 Hz
100 G for 11 ms
Shock
Life
1 million cycles min.
Insulation resistance
Maximum ratings
Voltage version “K”
Voltage version “L”
100 mΩ at 50 Vdc
Supply voltage VS = +15 Vdc
Supply current IS = +2.0 mA
PERFORMANCE CHARACTERISTICS – COMPENSATED SERIES (1)
Characteristic
Minimum
Typical
0
0.1
0.015
0.010
0.5
0.5
0.1
0.1
0.1
Maximum
+2
0.25
0.030
0.030
1.0
1.0
0.3
0.3
Units
mV
Zero pressure offset
-2
–
–
–
–
–
–
–
–
Pressure non-linearity (3)
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Pressure hysteresis (3)
Repeatability
Temp. effect on span (4)
Temp. effect on offset (4)
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
Long-term stability of offset and span (5)
Response time (6)
–
Common mode voltage (voltage version “K”) (9)
Input resistance (current version “L”)
Input resistance (voltage version “K”)
Output resistance
0.50
2.0
8.0
3.0
1.25
4.5
25
2.0
8.0
50
Vdc
kΩ
kΩ
kΩ
4.5
6.0
PRESSURE RANGE SPECIFICATIONS – COMPENSATED SERIES
Catalog Listing
Pressure range
0 psi to 500 psi
0 psi to 1000 psi
0 psi to 2000 psi
0 psi to 3000 psi
0 psi to 5000 psi
Full scale span (2)
98 mV to 102 mV
98 mV to 102 mV
98 mV to 102 mV
98 mV to 102 mV
Proof pressure (7)
1500 psi
3000 psi
6000 psi
Burst pressure (8)
2500 psi
13C 0500P (A,S) (1,4,5,6) (K,L)
13C 1000P (A,S) (1,4,5,6) (K,L)
13C 2000P (A,S) (1,4,5,6) (K,L)
13C 3000P (A,S) (1,4,5,6) (K,L)
13C 5000P (A,S) (1,4,5,6) (K,L)
NOTES
5000 psi
10,000 psi
10,000 psi
10,000 psi
9000 psi
148 mV to 152 mV 10,000 psi
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; Supply VS = 10 Vdc 0.01 Vdc or IS = 1.5 mA
0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
9. Common mode voltage as measure from output to ground.
2 Honeywell • Sensing and Control