5秒后页面跳转
1200110 PDF预览

1200110

更新时间: 2022-02-26 14:02:57
品牌 Logo 应用领域
西克 - SICK /
页数 文件大小 规格书
9页 2221K
描述
MULTIPLE LIGHT BEAM SAFETY DEVICES

1200110 数据手册

 浏览型号1200110的Datasheet PDF文件第3页浏览型号1200110的Datasheet PDF文件第4页浏览型号1200110的Datasheet PDF文件第5页浏览型号1200110的Datasheet PDF文件第7页浏览型号1200110的Datasheet PDF文件第8页浏览型号1200110的Datasheet PDF文件第9页 
M40S-025013AA0, M40E-025033RB0 | M4000 Advanced  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Connection diagram  
A
B
C
D
E
F
M4000 Advanced with UE403 switching amplifier connected to UE10-3OS safety relay  
+24 V  
A1  
A2  
+24V  
Test  
n.c.  
n.c.  
n.c.  
n.c.  
n.c.  
EFIa  
EFIb  
n.c.  
GND  
FE  
+24V  
RES  
1
3
1
5
S2  
S1  
+
- Q  
H3  
+
- Q  
EDM  
EFia  
4
6
5
9
1 2 3 4 5  
-
1 2 3 4 5  
IN  
1 2 3 4 5  
+
EFib  
6
10  
3
+
RR  
IN IN  
+
T
-
T
-
IN  
OSSD1  
OSSD2  
BS/C1  
ADO  
RES/OVR  
COM  
A1  
A2  
7
5
8
4
UE403  
11  
7
9
10  
11  
2
B2  
-
B1  
-
L
-
+
T
IN  
+
T
IN  
RR  
8
1 2 3 4 5  
H1  
1 2 3 4 5  
1 2 3 4 5  
GND  
FE  
2
FE  
FE  
5
+
-
Q
B2  
+
-
COM  
M4000S  
B1 B3 Y1 13 23 33 41  
Q
B1  
1)  
Advanced  
H
I
M4000R  
Advanced  
UE10-3OS  
B2 B4 Y2  
14 24  
34  
42  
0 V  
E119906/00/2014-07-29  
J
2) PELV  
Task  
Connection of an M4000 Advanced multiple light beam safety device with UE403 switching amplifier to a UE10-3OS safety relay.  
Muting with 4 photoelectric reflex switches (dark-switching, PNP).  
Operating mode: with restart interlock and external device monitoring.  
K
L
Operating characteristics  
When the light path is clear and the UE10-3OS is de-energized and functioning correctly, the yellow LED on the receiver and the H3  
lamp flash. The system is ready for switch-on and waits for an input signal/switch-on signal. The system is enabled by pressing and  
releasing the S1 button. The OSSD1 and OSSD2 outputs are live, the UE10-3OS is switched on. On interruption of one or several of  
the light beams, the UE10-3OS is de-energized by the OSSD1 and OSSD2 outputs.  
Muting and override  
M
N
O
P
Q
R
S
T
When the light path is clear and the muting input conditions are valid, muting starts. The H1 muting lamp illuminates. Different  
time and monitoring functions can be configured.  
When the light path is interrupted and muting sensors are active, e.g., because of muting errors or a new power on, override is en-  
abled by pressing and releasing the S2 button.  
Fault analysis  
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The erroneous behavior of the  
UE10-3OS will be detected. The shutdown function is retained. On manipulation (e.g., jamming) of the S1 button, the system does  
not enable the output current circuits.  
The failure of one muting sensor will be detected by the muting sequence and prohibit a new muting cycle. On manipulation (e.g.,  
jamming) of the S2 button, the system does not enable override. A permanent use of the override function will be inhibited through  
the device.  
Comments  
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state  
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z  
path) is only possible with a single-channel control and by taking the risk analysis into account.  
2) PELV in accordance with the requirements in  
EN 60204-1 / 6.4  
Take note of the operating instructions of the integrated devices. This applies particularly to the use of configurable functions.  
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
Online data sheet | 2017-08-24 18:11:25  
Subject to change without notice  

与1200110相关器件

型号 品牌 描述 获取价格 数据表
1200110017 MOLEX Micro-Change (M12) Receptacle, 4 Poles, M12x1 and M14x1 Threads, Male

获取价格

1200110033 MOLEX Circular Connector,

获取价格

1200110035 MOLEX Micro-Change (M12) Receptacle, 5 Poles, M12x1 and M14x1 Threads, Male

获取价格

1200110238 MOLEX Circular Connector,

获取价格

1200110281 MOLEX Circular Connector,

获取价格

1200111 SICK MULTIPLE LIGHT BEAM SAFETY DEVICES

获取价格