Thermal Circuit Breaker 1115-...
Description
Single pole thermal reset circuit breaker
l
Space-saving, slim design
Ease of installation through snap-in frame
Reliable, trip-free mechanism
Approvals: UL1077, EN60934
l
l
l
l
Attractively low price
Typical applications
Power supply units, UPS equipment, battery chargers, oxygen treat-
ment devices, office machines
1
1115
Order numbering code
Technical Data
Type No.
1115 single pole thermal circuit breaker
Mounting method
Rated voltage
Current rating range
Typical life
AC 250 V; DC 32 V
1...16 A
F1 snap-in mounting
Number of poles
500 operations at 1.5 times rated
current, resistive load, AC 125 V
1 1 pole, thermally protected
Accessories, style
1 black push button
Terminals
50 operations at 2 times rated
current, inductive load, AC 250 V
P1 blade terminals A 6.3 x 0.8 mm
Characteristic curve
T1 thermal 3...16 A
T2 thermal 1...2.5 A
Current ratings
Rupture capacity
UL1077
1.000 A (C, 1), AC 250 V
200 A (C, 1), DC 32 V
500 A (INC1), AC 250 V
EN 60934
Ambient temperature
Vibration
-20°C … + 60°C
57 Hz acceleration 30m/s2 (3g)
in X, Y, Z directions (twice/min.)
1...16A
1115 - F1 1 1 -P1 T1 - 10 A ordering example
Shock
Mass
300m/s2 (30g) in X, Y, Z directions
approx. 8g
Approvals
Current
rating
range
Current ratings and typical voltage drop
Approval
authority
Rated
Approval
mark
Standard
voltage
Current rating Voltage drop
Current rating Voltage drop
UL
UL1077
AC 250 V
DC 32 V
1...16 A
range (A)
(mV)
range (A)
(mV)
(E67320)
1
< 1000
8
< 250
TÜV
EN 60934/
IEC 60934
AC 250 V
1...16 A
1,5
2
< 500
< 500
< 500
< 250
< 250
< 250
< 250
< 250
< 250
9
< 250
< 250
< 250
< 250
< 250
< 250
< 250
< 250
10
11
12
13
14
15
16
2,5
3
Cut-out dimensions
1ꢀꢁꢂ ꢃ ꢄꢁꢅ
ꢆ ꢄ
3,5
4
5
6
7
1646
www.e-t-a.de
1