DIVISION OF DELTROL CORP.
SERIES RELAY
5 AND 10 AMP
100 GENERAL PURPOSE
100U/101U
FEATURES
MODELS
■ Class F Coil Insulation System for 155°C
100:
5 & 10 Amp with Solder Lug Terminals
Total Temperature
■ Coil Molded in DuPont Rynite® for Environmental
100RF: With Diallyl Phthalate Panel For Switching RF
100U: 5 Amp Unit with UL and CSA Recognition
101U: 10 Amp Unit with UL and CSA Recognition
101UP: 10 Amp Unit with Printed Circuit Terminals
Protection
■ Unique Armature Stop Maintains Adjustment
CONTACT DATA
CONFIGURATION:
COIL DATA
RESISTANCE
IN OHMS
± 10%
NOMINAL
COIL
POWER
Thru 3PDT
NOMINAL
VOLTAGE
MATERIALS:
5 AMP:
6VAC
12VAC
24VAC
48VAC
120VAC
240VAC
5.0
20
80
315
2025
8000
1/8" Diameter Moveable Fine Silver
3/16" Diameter Stationary Fine Silver
AC Coils
Single
Pole Units
2.0VA
2.2VA
1.2W
10 AMP:
3/16" Diameter Moveable Silver Cadmium Oxide
3/16" Diameter Stationary Fine Silver
Gold Flash is Standard on All Contacts
6VAC
12VAC
24VAC
48VAC
120VAC
240VAC
4.5
18
72
285
1850
7200
Gold Diffused Available on Special Order – Min. Qty. Req’d.
AC Coils
2 & 3
Pole Units
CONTACT RATINGS
MOVEABLE
CONTACT SIZE CONFIGURATION
POLE
UL
RATINGS*
6VDC
12VDC
24VDC
48VDC
110VDC
30
120
480
1/8 HP or 5 amp at
120VAC
1/4 HP or 5 amp at
277VAC
DC Coils
1-3
Pole Units
1/8" Diameter
3/16" Diameter
thru 3PDT
thru 3PDT
1850
10,000
5 amp at 28VDC
Coil Voltages: AC: Up to 277 Volts/60 Hz
DC: Up to 125 Volts
Coil Treatment: Molded Rynite® Std. Class F
Insulation Resistance: 100 Megohms Minimum
UL Insulation System File No.: E74443
10 amp or 1/3 HP
at 120VAC**
1/2 HP or 10 amp at
277VAC
10 amp at 28VDC
**UL/CSA On 100U/101U Series Only
S155D 155°C Total Temperature Std.
**3 Pole Devices Rated at 6-2/3 Amp When Switching
Greater Than 150VAC, Unless Polarity is the Same on
All Poles
(Covers S105 Class A and S130D Class B Requirements)
OPERATE DATA
Pick Up (at 25°C): AC Volts 85% or Less of Nominal
UL RECOGNIZED FILE NO.: E37066 (100U/101U Only)
CSA CERTIFIED FILE NO.: LR20690 (100U/101U Only)
DC Volts 75% or Less of Nominal
Operate Time:
Release Time:
Approx. 15 Milliseconds
Approx. 15 Milliseconds
EXPECTED LIFE
ENVIRONMENTAL DATA
Operating Ambient: AC: -45° to 70°C
Electrical At Rated Load (Minimum)
100,000 Operations
DC: -45° to 85°C
Mechanical Life
10,000,000 Operations
Coil Temperature Rise: (25°C Ambient – Continuous Duty)
AC: 45°C Approx. @ 60 Hz – Use at 50 Hz
will Cause Slight Increase in Coil Rise
DC: 25°C Approx.
DIELECTRIC STRENGTH
800 VRMS, 60 Hz Between Contacts
1500 VRMS (Model 100), 2200 VRMS
MECHANICAL DATA
Terminals: 100/100U/101U Pierced Solder Lugs .125" x .032"
(Model 100U/101U), 60 Hz Between Other Elements
100UP/101UP Printed Circuit Pins
Weight:
All Versions Approx. 2.0 oz. (57 g)
6