2
0RQB-X0S11x
MODEL
NUMBER
MODEL
NUMBER
OUTPUT
VOLTAGE
INPUT
VOLTAGE
MAX. OUTPUT
CURRENT
MAX. OUTPUT
POWER
TYPICAL
EFFICIENCY
0RQB-X0S11L
0RQB-X0S11B
0RQB-X0S11D
0RQB-X0S110
0RQB-X0S11A
0RQB-X0S11C
10.6 VDC
10.6 VDC
10.6 VDC
45 VDC - 58 VDC
45 VDC - 58 VDC
45 VDC - 58 VDC
94.3 A
94.3 A
94.3 A
1000 W
1000 W
1000 W
97.3%
97.3%
97.3%
NOTE: Add “G” suffix at the end of the model number to indicate Tray Packaging.
0
R
QB
-
X0
S
11
x
y
RoHS
Status
Series
Name
Output
Power
Input
Range
Output
Voltage
Package
Type
Mounting Type
Active Logic
0 – active high, Openframe
L – active low, Openframe
Through hole
mount
RoHS
6
1/4th
Brick
A – active high, with HSK plate
B – active low , with HSK plate
C – active high, with HSK with Fins
D – active low, with HSK with Fins
G – Tray
package
1000 W
45 – 58V
10.6 V
PARAMETER
DESCRIPTION
MIN
-0.3
-0.3
1500
-40
-40
-
TYP
MAX
80
UNITS
Continuous non-operating Input Voltage
Remote On/Off
-
-
-
-
-
-
-
V
V
18
I/O Isolation Voltage
Ambient Temperature
Storage Temperature
Altitude
-
V
85
C
C
m
%
125
4000
90
Relative Humidity
Operating, Non-Condensing
10
NOTE: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may permanently damage the device.
All specifications are typical at 25°C unless otherwise stated.
PARAMETER
DESCRIPTION
MIN
TYP
52
MAX
58
UNIT
V
Operating Input Voltage
Input Current (full load)
Input Current (no load)
45
-
-
28
A
-
100
150
mA
Remote Off Input Current
-
10
50
20
-
mA
mA
mA
mA
A2s
V
Input Reflected Ripple Current (rms)
Input Reflected Ripple Current (pk-pk)
Input Terminal Ripple Current Ic (RMS)
I2t Inrush Current Transient
-
Detail conditions please refer to input reflected
ripple current section.
-
200
-
-
-
1000
TBD
45.0
42.0
-
-
42.0
39.0
-
-
UVLO Turn on Voltage Threshold
UVLO Turn off Voltage Threshold
OVLO Turn off Voltage Threshold
OVLO Turn on Voltage Threshold
43.5
40.5
63
Input undervoltage lock-out(UVLO)
Input overvoltage lock-out(OVLO)
V
V
-
60
-
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application. Recommend a fast-acting fuse with
maximum rating of 30 A on system board. Refer to the fuse manufacture’s datasheet for further information.
tech.support@psbel.com